- Date
- 10/14/2020
- W/O
- 849528
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00819
- PipeID
- P17388
- Time
- 11:16 PM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K8161
- Sewer Name
- LORAINE TRUNK
- City
- GLENDORA
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 22
- Page No.
- 13
- Purpose
- Routine Assessment
- Project
- WO_849528_TV22055_SEP2020
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 22 1019
- Downstream MH
- 22 1018
- Dir. of Survey
- Downstream
- Length Surveyed
- 371.6 ft.
- Total Length
- 371.6 ft.
- Structural Index
- 3
- Structural Quick
- 3M2M
- Structural Rating
- 355
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 355
Pipe schematic from manhole 22 1019 to 22 1018 Observation photos (4)

0 ft. - General Observation - COCKROACHES IN MH

15.6 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

15.6 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

371.2 ft. - General Observation - COCKROACHES IN MH