Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 27, 2020, 05:40 AM
  • 29 0378_29 0377_10262020_220732.mp4

Date
10/26/2020
W/O
850036
Weather
Dry
Operator/Surveyor
b.fugate
Sewer ID
Z00537
PipeID
P24415
Time
10:40 PM
Certificate
u-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8137
Sewer Name
21ST STREET SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
04
Purpose
Routine Assessment
Project
WO_850036_TV29064_SEP2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0378
Downstream MH
29 0377
Dir. of Survey
Downstream
Length Surveyed
233.6 ft.
Total Length
233.6 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2H00
O&M Rating
92
Overall Index
2
Overall Quick
Overall Rating
92
Pipe schematic from manhole 29 0378 to 29 0377
MH: 29 0378MH: 29 0377downstream0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MGO - General Observation - CONN @ MH 5 O'CLOCK/ACTIVE0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 29 03782 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2.1 ft. MGO - General Observation - PIPE IS LINED5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4", 6" - OPEN74.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN176 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN231 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish233.6 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE233.6 ft. AMH - Downstream Manhole, Survey Ends - 29 0377

Observation photos (1)

  • Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4", 6" - OPEN

    5 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4", 6" - OPEN

Observations (12)

DistanceCodeObservation
233.6MGOCONN @ MH 3 O'CLOCK/ACTIVE
0MWM
231DAGS
233.6AMH29 0377
0MGOCONN @ MH 5 O'CLOCK/ACTIVE
74.5TFOPEN
2.1MGOPIPE IS LINED
2DAGS
0MWL
176TFOPEN
5TFOPEN
0AMH29 0378

Properties (8)

additional_info
6301026200075P1
custom_field_three
NO SEVERE DEFECTS
custom_field_two
4
customer
1
datetime
2020-10-26T22:40:21-07:00
documentation
PRO PIPE
is_lateral_inspection
false
lining
CIPP