Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 4, 2020, 09:18 AM
  • 02 0896_02 0895_1142020_013622.mp4

Date
11/04/2020
W/O
0855066
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00252
PipeID
P03464
Time
1:18 AM
Certificate
U-101406022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1614
Sewer Name
02 DOWNEY-BELLFLOWER DIVERSION TRUNK
City
DOWNEY
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
27
Purpose
Capital Improvement Program Assesment
Project
20201104MDM_DOWNEY_BELLFLOWER_DIVERSION_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Upstream MH
02 0896
Downstream MH
02 0895
Dir. of Survey
Downstream
Length Surveyed
347.3 ft.
Total Length
347.3 ft.
Structural Index
3
Structural Quick
3F2E
Structural Rating
161
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
161
Pipe schematic from manhole 02 0896 to 02 0895
MH: 02 0896MH: 02 0895downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 1:40AM0 ft. MWL - Water Level, 20 %of cross sectional area2 ft. MGO - General Observation - WHITE COATING OR BUILD UP ON TOP OF PIPE2 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - SLIGHT JOINT TO JOINT8 ft. FC - Fracture Circumferential, from 07 to 08 o'clock, within 8 inches of joint: YES - SLIGHT8 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - HAIRLINE8.5 ft. FC - Fracture Circumferential, from 03 to 05 o'clock, within 8 inches of joint: YES - SL (JOINT TO JOINT)8.5 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - H8.5 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES - SL10.3 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES, - SLIGHT14.3 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, - SL14.3 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - H19 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - H19 ft. FC - Fracture Circumferential, from 08 to 09 o'clock, within 8 inches of joint: YES - H21.4 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H21.4 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H25.2 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - H25.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H30.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H30.2 ft. FL - Fracture Longitudinal, at 04 o'clock, within 8 inches of joint: YES - H35.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H35.8 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES, Start - H40.5 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish - H40.9 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H45.5 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H51.3 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - H51.3 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H56.1 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - H61.6 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H61.6 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - H61.6 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H71.9 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H71.9 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H75.9 ft. FC - Fracture Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES - H75.9 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - H81.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish - H87.2 ft. FC - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES, - H87.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H112.5 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H112.5 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - H117.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H117.2 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H132.9 ft. FC - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES - H137.7 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - H149 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - H153.3 ft. FC - Fracture LONGITUDAL AT 12 o'clock, within 8 inches of joint: YES, Finish158.1 ft. FC - Fracture Circumferential, from 10 to 12 o'clock, within 8 inches of joint: YES - H158.1 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H163.9 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H163.9 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H168.5 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H188.6 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - H199.7 ft. FC - Fracture Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES - H214.3 ft. FC - Fracture Circumferential, from 10 to 01 o'clock, within 8 inches of joint: YES - H224.5 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H235.2 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES, Start - H240.2 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES, Finish - H250.6 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H265.7 ft. FC - Fracture Circumferential, from 02 to 03 o'clock, within 8 inches of joint: YES - H270.6 ft. FC - Fracture Circumferential, from 10 to 12 o'clock, within 8 inches of joint: YES - H276 ft. FC - Fracture Circumferential, from 10 to 12 o'clock, within 8 inches of joint: YES - H276 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H281.3 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - H286.2 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - H291.3 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - SL291.3 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H297.2 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - H297.2 ft. FC - Fracture Circumferential, from 08 to 09 o'clock, within 8 inches of joint: YES - H313.6 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - H332.3 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - H342.2 ft. FL - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES - H347.3 ft. AMH - Downstream Manhole, Survey Ends - 1:40AM

Observation photos (4)

  • General Observation - WHITE COATING OR BUILD UP ON TOP OF PIPE

    2 ft. - General Observation - WHITE COATING OR BUILD UP ON TOP OF PIPE

  • Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - SLIGHT JOINT TO JOINT

    2 ft. - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - SLIGHT JOINT TO JOINT

  • Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES,  - SLIGHT

    10.3 ft. - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES, - SLIGHT

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES,  - SL

    14.3 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, - SL

Observations (73)

DistanceCodeObservation
281.3FCH
270.6FCH
297.2FCH
35.8FLH
75.9FCH
291.3FCSL
137.7FCH
158.1FCH
71.9FLH
347.3AMH1:40AM
158.1FLH
168.5FLH
163.9FCH
132.9FCH
117.2FLH
214.3FCH
8FCSLIGHT
240.2FLH
19FCH
163.9FLH
235.2FLH
265.7FCH
30.2FLH
8.5FCSL (JOINT TO JOINT)
87.2FCH
61.6FCH
117.2FLH
87.2FLH
8FCHAIRLINE
8.5FCH
286.2FLH
276FCH
45.5FLH
19FCH
40.5FLH
149FLH
81.8FLH
75.9FLH
8.5FLSL
112.5FLH
0MWM
153.3FC
332.3FCH
10.3FLSLIGHT
61.6FLH
30.2FLH
40.9FLH
56.1FLH
112.5FCH
51.3FCH
188.6FCH
313.6FCH
342.2FLH
51.3FLH
199.7FCH
61.6FLH
0AMH1:40AM
21.4FLH
224.5FLH
250.6FCH
35.8FLH
2MGOWHITE COATING OR BUILD UP ON TOP OF PIPE
25.2FCH
0MWL
14.3FLSL
276FLH
2FLSLIGHT JOINT TO JOINT
291.3FCH
297.2FCH
21.4FLH
14.3FCH
71.9FLH
25.2FLH

Properties (6)

custom_field_three
SLIGHT & HAIRLINE FRACTURES JOINT TO JOINT LONGER
custom_field_two
2
customer
LACSD
datetime
2020-11-04T01:18:42-08:00
documentation
MARTIN,OLIVER 111,RUVALCABA
is_lateral_inspection
false