- Date
- 11/06/2020
- W/O
- 0854901
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00659
- PipeID
- P13618
- Time
- 2:26 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H1617
- Sewer Name
- 16 LAMANDA PARK TRUNK
- City
- PASADENA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 16
- Page No.
- 11
- Purpose
- Routine Assessment
- Project
- 20201105MDM_LAMANDA_PARK_TRUNK
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 22 in.
- Upstream MH
- 16 0567
- Downstream MH
- 16 0566
- Dir. of Survey
- Downstream
- Length Surveyed
- 191.8 ft.
- Total Length
- 191.8 ft.
- Structural Index
- 2
- Structural Quick
- 2300
- Structural Rating
- 6
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 8
Pipe schematic from manhole 16 0567 to 16 0566 Observation photos (5)

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING FLAKING CONCRETE UNDER MAG COAT

2 ft. - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE UNDER MAG COAT

2 ft. - General Observation - MAG COAT 99% START

27.9 ft. - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: NO - DEEP PEELING CONCRETE

135.8 ft. - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - ROCKE SLUDGE