Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 5, 2020, 10:03 AM
  • 16 0577_16 0576_1152020_025621.mp4

Date
11/05/2020
W/O
0854901
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00659
PipeID
P13628
Time
2:03 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1617
Sewer Name
16 LAMANDA PARK TRUNK
City
PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
11
Purpose
Routine Assessment
Project
20201105MDM_LAMANDA_PARK_TRUNK
Material
Reinforced Concrete Pipe
Shape
Circular
Height
18 in.
Upstream MH
16 0577
Downstream MH
16 0576
Dir. of Survey
Downstream
Length Surveyed
238.8 ft.
Total Length
238.8 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 16 0577 to 16 0576
MH: 16 0577MH: 16 0576downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 2:55AM0 ft. MWM - Water Mark, 15 %of cross sectional area2 ft. MMC - Material Change, Other (state in comments) - PIPE IS LINED2 ft. MGO - General Observation - MAG COAT 95% START70.4 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - Open82.5 ft. TB - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: NO, 6" - Open129.9 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6" - Active135.5 ft. TBA - Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: NO, 6" - Active159.8 ft. TB - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: NO, 6" - Open179.7 ft. MGO - General Observation - MAG COAT 80% START179.7 ft. MGO - General Observation - LINER UNDER MAG COAT204.3 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - Open233.4 ft. LFW - Lining Failure Wrinkled, from 04 to 08 o'clock, within 8 inches of joint: NO238.2 ft. MGO - General Observation - PIPE IS LINED238.2 ft. MGO - General Observation - 80% MAG COAT FINISH238.8 ft. AMH - Downstream Manhole, Survey Ends - 3:15AM

Observation photos (5)

  • Material Change, Other (state in comments) - PIPE IS LINED

    2 ft. - Material Change, Other (state in comments) - PIPE IS LINED

  • General Observation - MAG COAT 95% START

    2 ft. - General Observation - MAG COAT 95% START

  • General Observation - MAG COAT 80% START

    179.7 ft. - General Observation - MAG COAT 80% START

  • General Observation - LINER UNDER MAG COAT

    179.7 ft. - General Observation - LINER UNDER MAG COAT

  • Lining Failure Wrinkled, from 04 to 08 o'clock, within 8 inches of joint: NO

    233.4 ft. - Lining Failure Wrinkled, from 04 to 08 o'clock, within 8 inches of joint: NO

Observations (17)

DistanceCodeObservation
0MWL
233.4LFW
238.2MGOPIPE IS LINED
129.9TBAActive
2MMCPIPE IS LINED
204.3TBOpen
238.8AMH3:15AM
0AMH2:55AM
179.7MGOMAG COAT 80% START
82.5TBOpen
159.8TBOpen
0MWM
70.4TBOpen
179.7MGOLINER UNDER MAG COAT
238.2MGO80% MAG COAT FINISH
2MGOMAG COAT 95% START
135.5TBAActive

Properties (7)

additional_info
PIPE IS LINED
custom_field_three
LINER IN GOOD COND
custom_field_two
4
customer
LACSD
datetime
2020-11-05T02:03:49-08:00
documentation
MARTIN,OLIVER 111,CASTILLO,RUVALCABA
is_lateral_inspection
false