Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 29, 2020, 08:33 PM
  • H 0494_H 0493B_10292020_133817.mp4

Date
10/29/2020
W/O
0850190
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z00182
PipeID
P26621
Time
1:33 PM
Certificate
U-1014-06022541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1607
Sewer Name
H JOINT OUTFALL H - UNIT 7A
City
CITY OF INDUSTRY
Loc. details
Other
Location Code
Z
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
30
Purpose
Routine Assessment
Project
20201029SHO_JOINT_OUTFALL_H_UNIT_7A
Material
Reinforced Concrete Pipe
Shape
Circular
Height
48 in.
Upstream MH
H 0493B
Downstream MH
H 0494
Dir. of Survey
Upstream
Length Surveyed
2 ft.
Total Length
2 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole H 0493B to H 0494
MH: H 0493BMH: H 0494upstream0 ft. SSS - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: YES - MINOR SPALLING0 ft. AMH - Upstream Manhole, Survey Ends - ZOOMED TO MH 4942 ft. AMH - Downstream Manhole, Survey Begins - SIPHON???2 ft. MWL - Water Level, 35 %of cross sectional area2 ft. MWM - Water Mark, 45 %of cross sectional area

Observations (5)

DistanceCodeObservation
0AMHSIPHON???
2SSSMINOR SPALLING
0MWL
2AMHZOOMED TO MH 494
0MWM

Properties (7)

additional_info
SIPHON????
custom_field_three
VERY MINOR SPALLING
custom_field_two
4
customer
LACSD
datetime
2020-10-29T13:33:17-07:00
documentation
OBREGON, SHADLER, RAMIREZ
is_lateral_inspection
false