Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 28, 2020, 05:10 PM
  • H 0644_H 0643_10282020_104327.mp4

Date
10/28/2020
W/O
0855057
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z00192
PipeID
P11051
Time
10:10 AM
Certificate
U-1014-06022541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1604
Sewer Name
H JOINT OUTFALL H - UNIT 8J
City
LA PUENTE
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
24
Purpose
Capital Improvement Program Assesment
Project
20201027SHO_JOINT_OUTFALL_H_UNIT_8J
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
H 0644
Downstream MH
H 0643
Dir. of Survey
Downstream
Length Surveyed
331 ft.
Total Length
331 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
9
Pipe schematic from manhole H 0644 to H 0643
MH: H 0644MH: H 0643downstream0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - H 06440 ft. MWL - Water Level, 40 %of cross sectional area5.6 ft. SSS - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: YES, Start5.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start11.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"16.4 ft. MGO - General Observation - 10% MAG COAT INTACT44 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"48.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"108.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"125.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"165.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"194.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"202 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"226.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"234.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"279.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"310.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"315.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"319.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"323.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"330.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish330.1 ft. SSS - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish331 ft. AMH - Downstream Manhole, Survey Ends - H 0643

Observations (24)

DistanceCodeObservation
165.7TF
323.8TF
16.4MGO10% MAG COAT INTACT
48.1TF
315.7TF
226.6TF
11.3TF
125.2TF
279.3TF
0MWM
319.6TF
5.6SSS
330.1SAV
330.1SSS
202TF
5.6SAV
194.1TF
234.6TF
331AMHH 0643
44TF
0AMHH 0644
0MWL
310.8TF
108.9TF

Properties (6)

custom_field_three
SPALLING & AGG.
custom_field_two
2
customer
LACSD
datetime
2020-10-28T10:10:49-07:00
documentation
OBREGON, BRAR, RAMIREZ
is_lateral_inspection
false