- Date
- 10/15/2020
- W/O
- 849889
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00791
- PipeID
- P16855
- Time
- 10:09 PM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K8162
- Sewer Name
- BEN LOMOND TRUNK
- City
- COVINA
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 22
- Page No.
- 26
- Purpose
- Routine Assessment
- Project
- RFIR_WO_849889_TV22102_SEP2020
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 22 0515
- Downstream MH
- 22 0514
- Dir. of Survey
- Downstream
- Length Surveyed
- 444.9 ft.
- Total Length
- 444.9 ft.
- Structural Index
- 3
- Structural Quick
- 453Q
- Structural Rating
- 297
- O&M Index
- 2
- O&M Quick
- 412Q
- O&M Rating
- 180
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 477
Pipe schematic from manhole 22 0515 to 22 0514 Observation photos (7)

0 ft. - General Observation - ROACHES @ MH

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

98 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

216.6 ft. - Fracture Longitudinal Hinge, 2, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

319.5 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

429.4 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

444.2 ft. - General Observation - ROACHES @ MH