Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 5, 2020, 10:06 AM
  • 18 0232_18 1233 _10052020_031018.mp4

Date
10/05/2020
W/O
849677
Weather
Dry
Operator/Surveyor
b.fugate
Sewer ID
Z01188
PipeID
P26209
Time
3:06 AM
Certificate
u-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8111
Sewer Name
EAST IMPERIAL HIGHWAY RELIEF TRUNK
City
south whittier
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
26
Purpose
Routine Assessment
Project
WO_849677_TV18129_SEP2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
18 0232
Downstream MH
18 1233
Dir. of Survey
Downstream
Length Surveyed
17.3 ft.
Total Length
17.3 ft.
Structural Index
2
Structural Quick
2300
Structural Rating
6
O&M Index
2
O&M Quick
2300
O&M Rating
6
Overall Index
2
Overall Quick
Overall Rating
12
Pipe schematic from manhole 18 0232 to 18 1233
MH: 18 0232MH: 18 1233downstream0 ft. MWM - Water Mark, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 02320 ft. MWL - Water Level, 5 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start15 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish15 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish17.3 ft. AMH - Downstream Manhole, Survey Ends - 18 1233

Observations (8)

DistanceCodeObservation
2SSS
0MWM
15DAGS
2DAGS
15SSS
0AMH18 0232
0MWL
17.3AMH18 1233

Properties (8)

additional_info
6301005200066P1
custom_field_three
SPALLING
custom_field_two
3
customer
1
datetime
2020-10-05T03:06:42-07:00
documentation
propipe
is_lateral_inspection
false
year_laid
40099