Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 26, 2020, 07:58 AM
  • 17 0063_17 0062_10262020_010828.mp4

Date
10/26/2020
W/O
0855542
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00668
PipeID
P13782
Time
12:58 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1597
Sewer Name
17 DISTRICT #17 MAIN TRUNK
City
ALTADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 17
Page No.
03
Purpose
Maintenance Related
Project
20201023MDM_DISTRICT_17_MAIN_TRUNK
Material
NRCP
Shape
Circular
Height
18 in.
Upstream MH
17 0063
Downstream MH
17 0062
Dir. of Survey
Downstream
Length Surveyed
395.2 ft.
Total Length
395.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2111
O&M Rating
3
Overall Index
2
Overall Quick
Overall Rating
3
Pipe schematic from manhole 17 0063 to 17 0062
MH: 17 0063MH: 17 0062downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 1:00AM39.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6" - Capped198.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped293.8 ft. TFD - Tap Factory Made Defective, at 12 o'clock, -, within 8 inches of joint: NO, 6" - Active-70% ROOTS307.1 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR - 3%395.2 ft. AMH - Downstream Manhole, Survey Ends - 1:20AM

Observations (8)

DistanceCodeObservation
0MWL
307.1RFJ3%
0MWM
39.8TFCCapped
293.8TFDActive-70% ROOTS
0AMH1:00AM
395.2AMH1:20AM
198.9TFCCapped

Properties (5)

additional_info
CLEANING EVALUATION ONLY
customer
LACSD
datetime
2020-10-26T00:58:31-07:00
documentation
MARTIN,OLIVER 111,CASTILLO,RUVALCABA
is_lateral_inspection
false