- Date
- 10/24/2020
- W/O
- 0849547
- Weather
- Dry
- Operator/Surveyor
- FRANKLIN
- Sewer ID
- Z00112
- PipeID
- P09260
- Time
- 9:54 AM
- Certificate
- U-415-06024039
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- I0354
- Sewer Name
- JOINT OUTFALL B - UNIT 8J
- City
- ARCADIA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 15
- Page No.
- 12
- Purpose
- Routine Assessment
- Project
- 20201024DF_JOINT_OUTFALL_B_UNIT_8J
- Sewer Type
- Siphon
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 36 in.
- Upstream MH
- B 0793
- Downstream MH
- B 0791
- Dir. of Survey
- Downstream
- Length Surveyed
- 2.9 ft.
- Total Length
- 2.9 ft.
- Structural Index
- 3
- Structural Quick
- 3121
- Structural Rating
- 5
- O&M Index
- 4
- O&M Quick
- 5141
- O&M Rating
- 11
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 16
Pipe schematic from manhole B 0793 to B 0791 Observation photos (4)

0 ft. - General Photograph

0 ft. - Upstream Manhole, Survey Begins - 9:57 AM

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES