- Date
- 08/18/2020
- W/O
- 844678
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z01204
- PipeID
- P16288
- Time
- 1:55 AM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K7959
- Sewer Name
- JOINT OUTFALL H - UNIT 8M
- City
- WEST COVINA
- Loc. details
- Parking Lot
- Location Code
- G
- Use of Sewer
- Sanitary Sewer
- District
- District 22
- Page No.
- 30
- Purpose
- Routine Assessment
- Project
- WO_844678_TV22034_AUG2020
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 30 in.
- Width
- 30 in.
- Upstream MH
- H 1417
- Downstream MH
- H 1416
- Dir. of Survey
- Downstream
- Length Surveyed
- 533.1 ft.
- Total Length
- 533.1 ft.
- Structural Index
- 3
- Structural Quick
- 3222
- Structural Rating
- 10
- O&M Index
- 3
- O&M Quick
- 4132
- O&M Rating
- 14
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 24
Pipe schematic from manhole H 1417 to H 1416 Observation photos (5)

0 ft. - General Observation - COCKROACHES IN MANHOLE

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

332.8 ft. - Repair Patch, from 09 to 03 o'clock, within 8 inches of joint: YES - ABANDONED MH

511.9 ft. - Repair Patch, from 09 to 03 o'clock, within 8 inches of joint: YES - ABANDONED MH