Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 14, 2020, 09:41 AM
  • H 1379_H 1378_09142020_030430.mp4

Date
09/14/2020
W/O
844678
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01204
PipeID
P16254
Time
2:41 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8034
Sewer Name
JOINT OUTFALL H - UNIT 8M
City
WEST COVINA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
35
Purpose
Routine Assessment
Project
WO_844678_TV22034_AUG2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
39 in.
Width
39 in.
Upstream MH
H 1379
Downstream MH
H 1378
Dir. of Survey
Downstream
Length Surveyed
328.9 ft.
Total Length
328.9 ft.
Structural Index
2
Structural Quick
2L00
Structural Rating
130
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
130
Pipe schematic from manhole H 1379 to H 1378
MH: H 1379MH: H 1378downstream0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - H 13792 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start2.1 ft. MGO - General Observation - MAG COAT6.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"148 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"221.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"246.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"326 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish328.9 ft. AMH - Downstream Manhole, Survey Ends - H 1378328.9 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK

Observations (13)

DistanceCodeObservation
328.9AMHH 1378
0MGOCONNECTION AT MH 9 O'CLOCK
0MWL
328.9MGOCONNECTION AT MH 3 O'CLOCK
2.1MGOMAG COAT
0MWM
2SSS
148TFC
0AMHH 1379
6.2TFA
326SSS
221.9TFC
246.6TF

Properties (7)

additional_info
SC411847
custom_field_three
AGGREGATE VISIBLE
custom_field_two
4
customer
1
datetime
2020-09-14T02:41:36-07:00
documentation
PRO PIPE
is_lateral_inspection
false