- Date
- 09/17/2020
- W/O
- 849661
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00013
- PipeID
- P00379
- Time
- 10:53 PM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K8041
- Sewer Name
- KEYSTONE TRUNK
- City
- CARSON
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 08
- Page No.
- 13
- Purpose
- Routine Assessment
- Project
- RFIR_WO_849661_TV08155_SEP2020
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 12 in.
- Width
- 15 in.
- Upstream MH
- 08 0329
- Downstream MH
- 08 0330
- Dir. of Survey
- Upstream
- Length Surveyed
- 334.2 ft.
- Total Length
- 334.2 ft.
- Structural Index
- 3
- Structural Quick
- 4G3M
- Structural Rating
- 491
- O&M Index
- 2
- O&M Quick
- 2L00
- O&M Rating
- 132
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 623
Pipe schematic from manhole 08 0329 to 08 0330 Observation photos (5)

2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

70.2 ft. - Crack Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES

103.3 ft. - Crack Multiple, from 07 to 03 o'clock, within 8 inches of joint: YES

128.4 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

142.3 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start