Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 25, 2020, 07:00 AM
  • 08 0306_08 0305A_09252020_000508.mp4

Date
09/25/2020
W/O
849661
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00013
PipeID
P00355
Time
12:00 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8048
Sewer Name
KEYSTONE TRUNK
City
CARSON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
10
Purpose
Routine Assessment
Project
RFIR_WO_849661_TV08155_SEP2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
12 in.
Upstream MH
08 0306
Downstream MH
08 0305A
Dir. of Survey
Downstream
Length Surveyed
94.6 ft.
Total Length
94.6 ft.
Structural Index
2
Structural Quick
3B2C
Structural Rating
84
O&M Index
2
O&M Quick
2C00
O&M Rating
36
Overall Index
2
Overall Quick
Overall Rating
120
Pipe schematic from manhole 08 0306 to 08 0305A
MH: 08 0306MH: 08 0305Adownstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08 03060 ft. MGO - General Observation - ROACHES @ MH2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start13.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start53.3 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"92 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish92 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish94 ft. MGO - General Observation - ROACHES @ MH94.6 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE94.6 ft. AMH - Downstream Manhole, Survey Ends - 08 0305A94.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (1)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    13.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (15)

DistanceCodeObservation
0MWM
92DAGS
2DAGS
13.1CM
94.6MGOCONN @ MH 9 O'CLOCK/ACTIVE
53.3TFC
0MGOCONN @ MH 3 O'CLOCK/ACTIVE
0MWL
94.6AMH08 0305A
2SSS
92SSS
94MGOROACHES @ MH
0AMH08 0306
94.6CM
0MGOROACHES @ MH

Properties (7)

additional_info
SC411961
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2020-09-25T00:00:14-07:00
documentation
PROPIPE
is_lateral_inspection
false