Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 16, 2020, 03:59 PM
  • 29 0292_29 0286_09162020_092539.mp4

Date
09/16/2020
W/O
850185
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00375
PipeID
P24202
Time
8:59 AM
Certificate
U-109-7948
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7344
Sewer Name
ORANGE AVENUE SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
01
Purpose
Routine Assessment
Project
WO_850185_TV29040_SEP2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0292
Downstream MH
29 0286
Dir. of Survey
Downstream
Length Surveyed
298 ft.
Total Length
298 ft.
Structural Index
2
Structural Quick
2K00
Structural Rating
118
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
118
Pipe schematic from manhole 29 0292 to 29 0286
MH: 29 0292MH: 29 0286downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 29 02920 ft. MGO - General Observation - ROACHES @ MH0 ft. MWM - Water Mark, 10 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start19.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4" - OPEN21.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"66.5 ft. TB - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: NO, 4" - OPEN70.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"72.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"110.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"113.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"197.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"199.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"295 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish298 ft. AOC - Drop Connection, Survey Ends - 29 0286

Observations (16)

DistanceCodeObservation
295SSS
197.1TFC
70.3TFC
110.8TFC
0MWL
113.1TFC
2SSS
66.5TBOPEN
0AMH29 0292
0MGOROACHES @ MH
21.6TFC
0MWM
19.4TFOPEN
72.6TFC
298AOC29 0286
199.6TFC

Properties (8)

additional_info
SC411343
custom_field_three
LIGHT GREASE
custom_field_two
3
customer
1
datetime
2020-09-16T08:59:26-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
39295