01 1150_H 0077_10142020_010918.mp4
2 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG
2 ft. - General Observation - MAG COAT 60% START
24.4 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG
72.4 ft. - General Observation - MAG COAT 10% START
250.3 ft. - Surface Spalling, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - PEELING CONCRETE SEVERE AGG ATTACHED
308.2 ft. - Surface Spalling, from 11 to 01 o'clock, within 8 inches of joint: NO - MULTI LAYER PEELING CONCRETE SEVERE AQGG ATTACHED
380 ft. - Surface Missing Wall, at 12 o'clock, within 8 inches of joint: NO - 3" X3" SOIL VISIBLE
385 ft. - Surface Missing Wall, at 12 o'clock, within 8 inches of joint: NO - 3" X3" SOIL VISIBLE
386.9 ft. - Surface Missing Wall, at 12 o'clock, within 8 inches of joint: NO - 1" X1" SOIL VISIBLE
388.9 ft. - Surface Missing Wall, at 01 o'clock, within 8 inches of joint: YES - 1" X1" SOIL VISIBLE
388.9 ft. - Surface Missing Wall, from 11 to 12 o'clock, within 8 inches of joint: YES - 4" X1" SOIL VISIBLE
390.3 ft. - Surface Missing Wall, at 12 o'clock, within 8 inches of joint: NO - 3" X3" SOIL VISIBLE
391.3 ft. - Surface Missing Wall, from 11 to 01 o'clock, within 8 inches of joint: YES, Start - 72" LONG SOIL VISIBLE
393.7 ft. - General Photograph - SOIL VISIBLE
397.1 ft. - General Photograph - EXCAVATION SITE
397.8 ft. - Downstream Manhole, Survey Ends - 2:00AM(ATEXCAVATION SITE
| Distance | Code | Observation |
|---|---|---|
| 2 | SAM | SEVERE AGG |
| 393.7 | MGP | SOIL VISIBLE |
| 2 | MGO | MAG COAT 60% START |
| 0 | AMH | 12:55AM |
| 397.1 | SSS | PEELING CONCRETE SEVERE AGG ATTACHED |
| 397.1 | MGP | EXCAVATION SITE |
| 390.3 | SMW | 3" X3" SOIL VISIBLE |
| 0 | MWL | NO FLOW PLUG IN PLACE UPSTREAM |
| 397.8 | AMH | 2:00AM(ATEXCAVATION SITE |
| 386.9 | SMW | 1" X1" SOIL VISIBLE |
| 311.7 | MWL | STANDNG WATER |
| 397.1 | SMW | 72" LONG SOIL VISIBLE |
| 391.3 | SMW | 72" LONG SOIL VISIBLE |
| 0 | MWM | — |
| 385 | SMW | 3" X3" SOIL VISIBLE |
| 308.2 | SSS | MULTI LAYER PEELING CONCRETE SEVERE AQGG ATTACHED |
| 24.4 | SAM | SEVERE AGG |
| 250.3 | SSS | PEELING CONCRETE SEVERE AGG ATTACHED |
| 159.3 | MWM | — |
| 388.9 | SMW | 1" X1" SOIL VISIBLE |
| 397.1 | SAM | MISSING SEVERE AGG |
| 187.3 | TF | Active |
| 388.9 | SMW | 4" X1" SOIL VISIBLE |
| 380 | SMW | 3" X3" SOIL VISIBLE |
| 227 | MWM | — |
| 72.4 | MGO | MAG COAT 10% START |
| 397.1 | MGO | NO DEBRIE PROBLEMS OBSERVED |