Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 8, 2020, 10:11 AM
  • 15 0824_15 0823_1082020_031901.mp4

Date
10/08/2020
W/O
0855406
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00593
PipeID
P13025
Time
3:11 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1583R
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTS 2&5
City
ARCADIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
01
Purpose
Maintenance Related
Project
20201007MDM_ARCADIA_SIERRA_MADRE_TRUNK_SECTS_2_5
Material
NRCP
Shape
Circular
Height
9.420000076293945 in.
Upstream MH
15 0824
Downstream MH
15 0823
Dir. of Survey
Downstream
Length Surveyed
324.1 ft.
Total Length
324.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 15 0824 to 15 0823
MH: 15 0824MH: 15 0823downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 3:15AM111.7 ft. TB - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: NO, 6" - Active147.5 ft. TBA - Tap Break-In Active, at 11 o'clock, -, within 8 inches of joint: NO, 6" - Active219.5 ft. TB - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: NO, 6" - Open231.2 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - Open300.7 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - Open324.1 ft. AMH - Downstream Manhole, Survey Ends - 3:35AM

Observations (10)

DistanceCodeObservation
0MWL
147.5TBAActive
111.7TBActive
0MGOConn. @ Mh, 9 O' Clock. Active
324.1AMH3:35AM
219.5TBOpen
300.7TBOpen
231.2TBOpen
0MWM
0AMH3:15AM

Properties (6)

additional_info
POST ROOT EVALUATION ONLY
customer
LACSD
datetime
2020-10-08T03:11:24-07:00
documentation
MARTIN,OLIVER 111,CASTILLO
is_lateral_inspection
false
lining
CIPP