Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 7, 2020, 07:36 AM
  • 15 0850_15 0849_1072020_005621.mp4

Date
10/07/2020
W/O
0855229
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00594
PipeID
P12628
Time
12:36 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1581R
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTS 3&2A
City
SIERRA MADRE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
01
Purpose
Maintenance Related
Project
20201005MDM_ARCADIA_SIERRA_MADRE_TRUNK_SECTS_3_2A
Material
NRCP
Shape
Circular
Height
9.300000190734863 in.
Upstream MH
15 0850
Downstream MH
15 0849
Dir. of Survey
Downstream
Length Surveyed
132.7 ft.
Total Length
132.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 15 0850 to 15 0849
MH: 15 0850MH: 15 0849downstream0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active0 ft. AMH - Upstream Manhole, Survey Begins - 12:55AM0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area6 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6" - Open52.2 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - Open90.3 ft. TB - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: NO, 6" - Open93.1 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 6" - Active132 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. STUB132.7 ft. AMH - Downstream Manhole, Survey Ends - 1:10AM

Observations (10)

DistanceCodeObservation
132.7AMH1:10AM
0MGOConn. @ Mh, 3 O' Clock. Active
0AMH12:55AM
0MWM
52.2TBOpen
93.1TBAActive
6TBOpen
0MWL
132MGOConn. @ Mh, 9 O' Clock. STUB
90.3TBOpen

Properties (6)

additional_info
POST ROOT EVALUATION ONLY
customer
LACSD
datetime
2020-10-07T00:36:02-07:00
documentation
MARTIN,OLIVER,CASTILLO
is_lateral_inspection
false
lining
CIPP