Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 22, 2020, 05:48 AM
  • C 0165_C 0164_09212020_231458.mp4

Date
09/21/2020
W/O
850193
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00129
PipeID
P09678
Time
10:48 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8047
Sewer Name
JOINT OUTFALL C - UNIT 5B
City
LONG BEACH
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
10
Purpose
Routine Assessment
Project
WO_850193_TV19024_SEP2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
30 in.
Width
42 in.
Upstream MH
C 0165
Downstream MH
C 0164
Dir. of Survey
Downstream
Length Surveyed
452.3 ft.
Total Length
452.3 ft.
Structural Index
3
Structural Quick
3Q00
Structural Rating
270
O&M Index
2
O&M Quick
4134
O&M Rating
342
Overall Index
2
Overall Quick
Overall Rating
612
Pipe schematic from manhole C 0165 to C 0164
MH: C 0165MH: C 0164downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - C 01650 ft. MWL - Water Level, 20 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.4 ft. MGO - General Observation - 65% MAG COAT87.7 ft. ID - Infiltration Dripper, from 02 to 04 o'clock, within 8 inches of joint: YES87.7 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start271.3 ft. IR - Infiltration Runner, at 12 o'clock, within 8 inches of joint: YES376.5 ft. ID - Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES424.6 ft. ID - Infiltration Dripper, from 12 to 03 o'clock, within 8 inches of joint: YES444.3 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, at 06 o'clock, , within 8 inches of joint: YES450 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish452 ft. MGO - General Observation - ROACHES @ MH452.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish452.3 ft. AMH - Downstream Manhole, Survey Ends - C 0164452.3 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE452.3 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Finish452.3 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE

Observation photos (6)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Infiltration Dripper, from 02 to 04 o'clock, within 8 inches of joint: YES

    87.7 ft. - Infiltration Dripper, from 02 to 04 o'clock, within 8 inches of joint: YES

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock,  , within 8 inches of joint: YES, Start

    87.7 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start

  • Infiltration Runner, at 12 o'clock, within 8 inches of joint: YES

    271.3 ft. - Infiltration Runner, at 12 o'clock, within 8 inches of joint: YES

  • Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES

    376.5 ft. - Infiltration Dripper, at 12 o'clock, within 8 inches of joint: YES

  • Infiltration Dripper, from 12 to 03 o'clock, within 8 inches of joint: YES

    424.6 ft. - Infiltration Dripper, from 12 to 03 o'clock, within 8 inches of joint: YES

Observations (19)

DistanceCodeObservation
450DAGS
376.5ID
2DAGS
2.1SAP
0MWM
424.6ID
87.7ID
444.3DSZ
452.2SAP
452.3AMHC 0164
0AMHC 0165
87.7DAE
452.3MGOCONN @ MH 9 O'CLOCK/ACTIVE
0MWL
452.3DAE
271.3IR
2.4MGO65% MAG COAT
452MGOROACHES @ MH
452.3MGOCONN @ MH 3 O'CLOCK/ACTIVE

Properties (7)

additional_info
SC411960
custom_field_three
aggregate projecting
custom_field_two
3
customer
1
datetime
2020-09-21T22:48:51-07:00
documentation
PROPIPE
is_lateral_inspection
false