Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 17, 2020, 08:04 AM
  • E 0017_E 0016_09172020_012651.mp4

Date
09/17/2020
W/O
849880
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00027
PipeID
P07598
Time
1:04 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8039
Sewer Name
JOINT OUTFALL E - UNIT 1
City
COMPTON
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
20
Purpose
Routine Assessment
Project
RFIR_WO_849880_TV30070_SEP2020
Sewer Type
Siphon
Material
Reinforced Concrete Pipe
Shape
Circular
Height
48 in.
Width
15 in.
Upstream MH
E 0016
Downstream MH
E 0017
Dir. of Survey
Upstream
Length Surveyed
2.1 ft.
Total Length
2.1 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
4
O&M Quick
4131
O&M Rating
7
Overall Index
3
Overall Quick
Overall Rating
12
Pipe schematic from manhole E 0016 to E 0017
MH: E 0016MH: E 0017upstream0 ft. MSA - Survey Abandoned - VIEW OF U/S SIPHON FROM D/S MH0 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES0 ft. DAGS - Deposits Attached Grease, 20 %of cross sectional area, from 10 to 02 o'clock, , within 8 inches of joint: NO0.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES2.1 ft. AMH - Downstream Manhole, Survey Begins - E 00162.1 ft. MWM - Water Mark, 60 %of cross sectional area2.1 ft. MWL - Water Level, 45 %of cross sectional area

Observation photos (3)

  • Survey Abandoned - VIEW OF U/S SIPHON FROM D/S MH

    2.1 ft. - Survey Abandoned - VIEW OF U/S SIPHON FROM D/S MH

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Deposits Attached Grease, 20 %of cross sectional area, from 10 to 02 o'clock,  , within 8 inches of joint: NO

    2.1 ft. - Deposits Attached Grease, 20 %of cross sectional area, from 10 to 02 o'clock, , within 8 inches of joint: NO

Observations (7)

DistanceCodeObservation
2.1MSAVIEW OF U/S SIPHON FROM D/S MH
2.1SAV
2.1DAGS
0AMHE 0016
0MWM
2SSS
0MWL

Properties (8)

additional_info
SC411951
custom_field_three
AGGREGATE VISIBLE
custom_field_two
3
customer
1
datetime
2020-09-17T01:04:40-07:00
documentation
PROPIPE
is_lateral_inspection
false
lining
CIPP