Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 2, 2020, 08:53 AM
  • 02 2268_02 2267 _10022020_020744.mp4

Date
10/02/2020
W/O
849675
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00257
PipeID
P04520
Time
1:53 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8110
Sewer Name
DOWNEY-BELLFLOWER RELIEF TRUNK RELOCATION
City
DOWNEY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
32
Purpose
Routine Assessment
Project
RFIR_WO_849675_TV02404_SEP2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
8 in.
Upstream MH
02 2268
Downstream MH
02 2267
Dir. of Survey
Downstream
Length Surveyed
404.4 ft.
Total Length
404.4 ft.
Structural Index
3
Structural Quick
3O00
Structural Rating
240
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
240
Pipe schematic from manhole 02 2268 to 02 2267
MH: 02 2268MH: 02 2267downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 22683.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start42.8 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 6"404.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish404.4 ft. AMH - Downstream Manhole, Survey Ends - 02 2267404.4 ft. MGO - General Observation - ACTIVE CONNECTION AT MH 3 O'CLOCK

Observation photos (1)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
0MWL
404.4CM
0MWM
0AMH02 2268
404.4AMH02 2267
42.8TF
404.4MGOACTIVE CONNECTION AT MH 3 O'CLOCK
3.2CM

Properties (6)

custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2020-10-02T01:53:11-07:00
documentation
PROPIPE
is_lateral_inspection
false