Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 17, 2020, 08:37 AM
  • 32 1318_32 1317_09172020_014341.mp4

Date
09/17/2020
W/O
844702
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00843
PipeID
P19697
Time
1:37 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7996
Sewer Name
SOLEDAD CANYON RELIEF TRUNK
City
SANTA CLARITA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
11
Purpose
Routine Assessment
Project
WO_844702_TV32040_AUG2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
32 1318
Downstream MH
32 1317
Dir. of Survey
Downstream
Length Surveyed
123.3 ft.
Total Length
123.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
412D
O&M Rating
52
Overall Index
2
Overall Quick
Overall Rating
52
Pipe schematic from manhole 32 1318 to 32 1317
MH: 32 1318MH: 32 1317downstream0 ft. AMH - Upstream Manhole, Survey Begins - 32 13180 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start121.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish123.3 ft. AMH - Downstream Manhole, Survey Ends - 32 1317123.3 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
2DAGS
0AMH32 1318
0MWM
123.3AMH32 1317
0MWL
121.3DAGS
123.3MGOCONNECTION AT MH 3 O'CLOCK

Properties (8)

additional_info
SC411888
custom_field_three
LIGHT GREASE
custom_field_two
4
customer
1
datetime
2020-09-17T01:37:21-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
32808