Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 17, 2020, 07:21 AM
  • 32 1312_32 1311_09172020_005334.mp4

Date
09/17/2020
W/O
844702
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00843
PipeID
P19691
Time
12:21 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7996
Sewer Name
SOLEDAD CANYON RELIEF TRUNK
City
SANTA CLARITA
Loc. details
Parking Lot
Location Code
G
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
11
Purpose
Routine Assessment
Project
WO_844702_TV32040_AUG2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
32 1312
Downstream MH
32 1311
Dir. of Survey
Downstream
Length Surveyed
1040.3 ft.
Total Length
1040.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2i00
O&M Rating
416
Overall Index
2
Overall Quick
Overall Rating
416
Pipe schematic from manhole 32 1312 to 32 1311
MH: 32 1312MH: 32 1311downstream0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 32 13122 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start1027.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"1040.3 ft. AMH - Downstream Manhole, Survey Ends - 32 13111040.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
1040.3AMH32 1311
0MWL
2DAGS
1027.5TFC
0MWM
0AMH32 1312
1040.3DAGS

Properties (8)

additional_info
SC411887
custom_field_three
LIGHT GREASE
custom_field_two
4
customer
1
datetime
2020-09-17T00:21:57-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
32808