Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 4, 2020, 07:36 AM
  • 03 0038_03 0037_09042020_004931.mp4

Date
09/04/2020
W/O
844367
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00366
PipeID
P05058
Time
12:36 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8024
Sewer Name
LOS COYOTES DIAGONAL TRUNK
City
LAKEWOOD
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
13
Purpose
Routine Assessment
Project
RFIR_WO_844367_TV03159_AUG2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
21 in.
Upstream MH
03 0038
Downstream MH
03 0037
Dir. of Survey
Downstream
Length Surveyed
324.3 ft.
Total Length
324.3 ft.
Structural Index
3
Structural Quick
3H00
Structural Rating
138
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
138
Pipe schematic from manhole 03 0038 to 03 0037
MH: 03 0038MH: 03 0037downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MGO - General Observation - CONNECTION @ U/S MH - 9 O'CLOCK - UNKNOWN STATUS0 ft. AMH - Upstream Manhole, Survey Begins - 03 00380 ft. MWL - Water Level, 15 %of cross sectional area8.7 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ACTIVE65.3 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 6"84.1 ft. CM - Crack Multiple, from 01 to 05 o'clock, within 8 inches of joint: YES98.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start121.7 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"162.7 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ACTIVE198.8 ft. TS - Tap Saddle, at 02 o'clock, -, within 8 inches of joint: NO, 6"245 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"303.9 ft. TS - Tap Saddle, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ACTIVE324.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish324.3 ft. AMH - Downstream Manhole, Survey Ends - 03 0037

Observation photos (7)

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 6"

    65.3 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 6"

  • Crack Multiple, from 01 to 05 o'clock, within 8 inches of joint: YES

    84.1 ft. - Crack Multiple, from 01 to 05 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    98.9 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    121.7 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ACTIVE

    162.7 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ACTIVE

  • Tap Saddle, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    198.8 ft. - Tap Saddle, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Saddle, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ACTIVE

    303.9 ft. - Tap Saddle, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ACTIVE

Observations (15)

DistanceCodeObservation
84.1CM
245TF
0MWM
98.9CM
324.3CM
198.8TS
162.7TBACTIVE
65.3TB
0MGOCONNECTION @ U/S MH - 9 O'CLOCK - UNKNOWN STATUS
121.7TB
324.3AMH03 0037
303.9TSACTIVE
0AMH03 0038
0MWL
8.7TBACTIVE

Properties (7)

additional_info
SC411837
custom_field_three
multiple cracks
custom_field_two
3
customer
1
datetime
2020-09-04T00:36:03-07:00
documentation
PROPIPE
is_lateral_inspection
false