Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 3, 2020, 11:29 AM
  • 15 0775_15 0774_1032020_043222.mp4

Date
10/03/2020
W/O
0855540
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00593
PipeID
P12976
Time
4:29 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1577R
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTS 2&5
City
ARCADIA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
04
Purpose
Maintenance Related
Project
20201002MDM_ARCADIA_SIERRA_MADRE_TRUNK
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
15 0774
Downstream MH
15 0775
Dir. of Survey
Upstream
Length Surveyed
385.3 ft.
Total Length
385.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
3322
O&M Rating
14
Overall Index
2
Overall Quick
Overall Rating
14
Pipe schematic from manhole 15 0774 to 15 0775
MH: 15 0774MH: 15 0775upstream0 ft. AMH - Downstream Manhole, Survey Ends - 4:55AM38.2 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6" - Capped41.2 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6" - Capped111.3 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 6", 6" - Open116.8 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6" - Capped193.3 ft. TFD - Tap Factory Made Defective, at 01 o'clock, -, within 8 inches of joint: YES, 6" - Open-60% ROOTS199.3 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Active214.8 ft. RFJ - Roots Fine Joint, from 04 to 05 o'clock, within 8 inches of joint: YESR - 2%233.3 ft. RMJ - Roots Medium Joint, from 07 to 05 o'clock, 15 %, within 8 inches of joint: YESR239 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6" - Capped240.4 ft. RMC - Roots Medium Connection, from 01 to 05 o'clock, 20 %, within 8 inches of joint: YES240.4 ft. TFD - Tap Factory Made Defective, at 01 o'clock, -, within 8 inches of joint: YES, 6" - Active-70% ROOTS249.7 ft. RMJ - Roots Medium Joint, from 08 to 04 o'clock, 10 %, within 8 inches of joint: YESR287.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped289.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped385.3 ft. MWM - Water Mark, 30 %of cross sectional area385.3 ft. MWL - Water Level, 10 %of cross sectional area385.3 ft. AMH - Downstream Manhole, Survey Begins - 4:35AM385.3 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active

Observation photos (3)

  • Roots Medium Joint, from 08 to 04 o'clock, 10 %, within 8 inches of joint: YESR

    135.6 ft. - Roots Medium Joint, from 08 to 04 o'clock, 10 %, within 8 inches of joint: YESR

  • Roots Medium Connection, from 01 to 05 o'clock, 20 %, within 8 inches of joint: YES

    144.9 ft. - Roots Medium Connection, from 01 to 05 o'clock, 20 %, within 8 inches of joint: YES

  • Roots Medium Joint, from 07 to 05 o'clock, 15 %, within 8 inches of joint: YESR

    152 ft. - Roots Medium Joint, from 07 to 05 o'clock, 15 %, within 8 inches of joint: YESR

Observations (19)

DistanceCodeObservation
146.3TFCCapped
95.9TFCCapped
268.5TFCCapped
186TFActive
0MWM
274TBOpen
0MWL
192TFDOpen-60% ROOTS
385.3AMH4:55AM
135.6RMJ
97.9TFCCapped
152RMJ
144.9RMC
0AMH4:35AM
347.1TFCCapped
170.5RFJ2%
344.1TFCCapped
144.9TFDActive-70% ROOTS
0MGOConn. @ Mh, 9 O' Clock. Active

Properties (5)

additional_info
POST ROOT EVALUATION ONLY
customer
LACSD
datetime
2020-10-03T04:29:40-07:00
documentation
MARTIN,OLIVER 111,CASTILLO
is_lateral_inspection
false