05 0293_05 0292_9302020_031823.mp4
2 ft. - Deposits Attached Grease, 15 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start
2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE
8 ft. - Surface Spalling, from 09 to 11 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE
14.8 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC
49.2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - PEELING CONCRETE
97.8 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC
| Distance | Code | Observation |
|---|---|---|
| 8 | SSS | BLISTERING CONCRETE |
| 2 | DAGS | — |
| 318.4 | DAGS | — |
| 97.8 | SAV | SEVERE AGG SPORATIC |
| 318.4 | MGO | Conn. @ Mh, 3 O' Clock. Active |
| 2 | SSS | BLISTERING PEELING CONCRETE |
| 49.2 | SSS | PEELING CONCRETE |
| 318.4 | SSS | BLISTERING PEELING CONCRETE |
| 318.4 | SAV | SEVERE AGG SPORATIC |
| 318.8 | AMH | 3:45AM |
| 0 | MWM | — |
| 14.8 | SAV | SEVERE AGG SPORATIC |
| 318.4 | MGO | Conn. @ Mh, 9 O' Clock. Active |
| 0 | AMH | 3:20AM |
| 0 | MWL | — |