Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 3, 2020, 08:51 AM
  • B 1527_B 1560_1032020_021637.mp4

Date
10/03/2020
W/O
0849545
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z01207
PipeID
P13299
Time
1:51 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1178
Sewer Name
B JOINT OUTFALL B - UNIT 6M
City
ALHAMBRA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
20
Purpose
Routine Assessment
Project
20201003MDM_JOINT_OUTFALL_B_UNIT_6M
Material
NRCP
Shape
Circular
Height
21 in.
Upstream MH
B 1527
Downstream MH
B 1560
Dir. of Survey
Downstream
Length Surveyed
12.7 ft.
Total Length
12.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole B 1527 to B 1560
MH: B 1527MH: B 1560downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active LARGE INCOMING0 ft. AMH - Upstream Manhole, Survey Begins - 2:15AM2 ft. MMC - Material Change, Vitrified clay pipe - PIPE IS VCP NOT NRCP2 ft. MGO - General Observation - 21" VCP12 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active12.7 ft. AMH - Downstream Manhole, Survey Ends - 2:20AM

Observation photos (2)

  • Material Change, Vitrified clay pipe - PIPE IS VCP NOT NRCP

    2 ft. - Material Change, Vitrified clay pipe - PIPE IS VCP NOT NRCP

  • General Observation - 21" VCP

    2 ft. - General Observation - 21" VCP

Observations (8)

DistanceCodeObservation
0MWM
2MMCPIPE IS VCP NOT NRCP
0MWL
0MGOConn. @ Mh, 3 O' Clock. Active LARGE INCOMING
12MGOConn. @ Mh, 3 O' Clock. Active
12.7AMH2:20AM
0AMH2:15AM
2MGO21" VCP

Properties (6)

custom_field_three
VCP PIPE GOOD COND-NOT NRCP
custom_field_two
4
customer
LACSD
datetime
2020-10-03T01:51:55-07:00
documentation
MARTIN,OLIVER 111,CASTILLO
is_lateral_inspection
false