Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 6, 2020, 04:41 AM
  • 05 2226_05 2225_08052020_215156.mp4

Date
08/05/2020
W/O
844901
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00555
PipeID
P07550
Time
9:41 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7940
Sewer Name
SO HAWTHORNE-WARFIELD AV EXT RELF TR, SECTS 4B&4D
City
HAWTHORNE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
19
Purpose
Routine Assessment
Project
WO_844901_TV05274_AUG2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
24 in.
Upstream MH
05 2226
Downstream MH
05 2225
Dir. of Survey
Downstream
Length Surveyed
347.2 ft.
Total Length
347.2 ft.
Structural Index
2
Structural Quick
2[00
Structural Rating
276
O&M Index
2
O&M Quick
2M00
O&M Rating
138
Overall Index
2
Overall Quick
Overall Rating
414
Pipe schematic from manhole 05 2226 to 05 2225
MH: 05 2226MH: 05 2225downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 22260 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. CS - Crack Spiral, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start345 ft. CS - Crack Spiral, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish345 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish345 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish347.2 ft. AMH - Downstream Manhole, Survey Ends - 05 2225

Observations (10)

DistanceCodeObservation
345CS
347.2AMH05 2225
2SSS
345DAGS
0AMH05 2226
0MWM
2CS
345SSS
0MWL
2DAGS

Properties (8)

additional_info
SC411800
custom_field_three
SPALLING
custom_field_two
3
customer
1
datetime
2020-08-05T21:41:00-07:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
27103