Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 6, 2020, 09:38 AM
  • 05 2218_05 2217_08062020_025151.mp4

Date
08/06/2020
W/O
844901
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00555
PipeID
P07542
Time
2:38 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7940
Sewer Name
SO HAWTHORNE-WARFIELD AV EXT RELF TR, SECTS 4B&4D
City
HAWTHORNE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
19
Purpose
Routine Assessment
Project
WO_844901_TV05274_AUG2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
21 in.
Upstream MH
05 2218
Downstream MH
05 2217
Dir. of Survey
Downstream
Length Surveyed
422.9 ft.
Total Length
422.9 ft.
Structural Index
3
Structural Quick
3P2P
Structural Rating
420
O&M Index
2
O&M Quick
2P00
O&M Rating
168
Overall Index
2
Overall Quick
Overall Rating
588
Pipe schematic from manhole 05 2218 to 05 2217
MH: 05 2218MH: 05 2217downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 22180 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start420 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish420 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish420 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish422.9 ft. AMH - Downstream Manhole, Survey Ends - 05 2217

Observations (10)

DistanceCodeObservation
422.9AMH05 2217
0AMH05 2218
2CM
420DAGS
0MWM
420SSS
0MWL
2DAGS
2SSS
420CM

Properties (8)

additional_info
SC411800
custom_field_three
SPALLING
custom_field_two
3
customer
1
datetime
2020-08-06T02:38:00-07:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
27103