Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 9, 2020, 05:40 AM
  • 01 0272_01 0271_09082020_225458.mp4

Date
09/08/2020
W/O
844481
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00218
PipeID
P01320
Time
10:40 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8029
Sewer Name
SOUTH PARK AVENUE TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
09
Purpose
Routine Assessment
Project
WO_844481_TV01060_AUG2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
18 in.
Upstream MH
01 0272
Downstream MH
01 0271
Dir. of Survey
Downstream
Length Surveyed
322.8 ft.
Total Length
322.8 ft.
Structural Index
3
Structural Quick
433L
Structural Rating
332
O&M Index
2
O&M Quick
312L
O&M Rating
131
Overall Index
2
Overall Quick
Overall Rating
463
Pipe schematic from manhole 01 0272 to 01 0271
MH: 01 0272MH: 01 0271downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE0 ft. AMH - Upstream Manhole, Survey Begins - 01 02722 ft. FM - Fracture Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start90.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"117.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"120.4 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN174.9 ft. TBD - Tap Break-In Defective, at 12 o'clock, -, , within 8 inches of joint: YES, 4", 4" - 5% ROOTS-LATERAL/OPEN192.1 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"197.4 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES207.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"234.9 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4", 6"238.9 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES267.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"320 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish320 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish322.8 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE322.8 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/CAPPED322.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish322.8 ft. AMH - Downstream Manhole, Survey Ends - 01 0271

Observation photos (6)

  • Fracture Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES

    2 ft. - Fracture Multiple, from 01 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

    120.4 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    192.1 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    197.4 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    238.9 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (24)

DistanceCodeObservation
174.9TBD5% ROOTS-LATERAL/OPEN
2FM
320DAGS
322.8MGOCONN @ MH 3 O'CLOCK/ACTIVE
197.4FM
0MWL
2CM
267.6TFC
320SSS
322.8MGOCONN @ MH 9 O'CLOCK/CAPPED
120.4TBOPEN
0MWM
322.8CM
2DAGS
234.9TFA
117.8TFC
0MGOCONN @ MH 3 O'CLOCK/ACTIVE
0AMH01 0272
192.1TB
322.8AMH01 0271
90.9TFC
238.9FM
207.7TFC
2SSS

Properties (7)

additional_info
SC411842
custom_field_three
MULTIPLE FRACTURES
custom_field_two
2
customer
1
datetime
2020-09-08T22:40:06-07:00
documentation
PROPIPE
is_lateral_inspection
false