- Date
- 09/01/2020
- W/O
- 845648
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00019
- PipeID
- P00548
- Time
- 9:31 PM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K8014
- Sewer Name
- SEPULVEDA-FIGUEROA STREET CONNECTING TRUNK
- City
- CARSON
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 08
- Page No.
- 13
- Purpose
- Routine Assessment
- Project
- WO_845648_TV08028_AUG2020
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 12 in.
- Width
- 48 in.
- Upstream MH
- 08 0490
- Downstream MH
- 08 0489
- Dir. of Survey
- Downstream
- Length Surveyed
- 177.7 ft.
- Total Length
- 177.7 ft.
- Structural Index
- 3
- Structural Quick
- 3521
- Structural Rating
- 17
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 17
Pipe schematic from manhole 08 0490 to 08 0489 Observation photos (6)

3.9 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

10.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

13.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

123.5 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

157 ft. - Crack Multiple, from 10 to 01 o'clock, within 8 inches of joint: YES

160.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES