Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 2, 2020, 04:31 AM
  • 08 0490_08 0489 _09012020_214525.mp4

Date
09/01/2020
W/O
845648
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00019
PipeID
P00548
Time
9:31 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8014
Sewer Name
SEPULVEDA-FIGUEROA STREET CONNECTING TRUNK
City
CARSON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
13
Purpose
Routine Assessment
Project
WO_845648_TV08028_AUG2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
48 in.
Upstream MH
08 0490
Downstream MH
08 0489
Dir. of Survey
Downstream
Length Surveyed
177.7 ft.
Total Length
177.7 ft.
Structural Index
3
Structural Quick
3521
Structural Rating
17
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
17
Pipe schematic from manhole 08 0490 to 08 0489
MH: 08 0490MH: 08 0489downstream0 ft. AMH - Upstream Manhole, Survey Begins - 08 04900 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 5 %of cross sectional area3.9 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES10.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES13.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start18.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"61.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"84.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish115.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"123.5 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES157 ft. CM - Crack Multiple, from 10 to 01 o'clock, within 8 inches of joint: YES160.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES164.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"177.7 ft. AMH - Downstream Manhole, Survey Ends - 08 0489

Observation photos (6)

  • Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    3.9 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    10.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    13.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    123.5 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 10 to 01 o'clock, within 8 inches of joint: YES

    157 ft. - Crack Multiple, from 10 to 01 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    160.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

Observations (15)

DistanceCodeObservation
123.5CM
84.6CM
115.6TFC
13.6CM
61.1TFC
0AMH08 0490
0MWL
160.6CM
0MWM
18.1TFC
164.8TFC
10.1CM
177.7AMH08 0489
3.9CL
157CM

Properties (7)

additional_info
SC411827
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2020-09-01T21:31:34-07:00
documentation
PROPIPE
is_lateral_inspection
false