Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 2, 2020, 05:10 AM
  • 08 0487_08 0486 _09012020_222634.mp4

Date
09/01/2020
W/O
845648
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00019
PipeID
P00545
Time
10:10 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8014
Sewer Name
SEPULVEDA-FIGUEROA STREET CONNECTING TRUNK
City
CARSON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
13
Purpose
Routine Assessment
Project
WO_845648_TV08028_AUG2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
36 in.
Upstream MH
08 0487
Downstream MH
08 0486
Dir. of Survey
Downstream
Length Surveyed
339.1 ft.
Total Length
339.1 ft.
Structural Index
4
Structural Quick
4131
Structural Rating
7
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
7
Pipe schematic from manhole 08 0487 to 08 0486
MH: 08 0487MH: 08 0486downstream0 ft. AMH - Upstream Manhole, Survey Begins - 08 04870 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 5 %of cross sectional area4.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start13.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"33.4 ft. FM - Fracture Multiple, from 12 to 01 o'clock, within 8 inches of joint: YES62.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"67.6 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"113.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"166 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"217.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"272.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"312.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"339.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish339.1 ft. AMH - Downstream Manhole, Survey Ends - 08 0486

Observation photos (3)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 12 to 01 o'clock, within 8 inches of joint: YES

    33.4 ft. - Fracture Multiple, from 12 to 01 o'clock, within 8 inches of joint: YES

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    67.6 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

Observations (15)

DistanceCodeObservation
272.6TFC
0AMH08 0487
4.3CM
0MWL
339.1CM
0MWM
67.6TB
339.1AMH08 0486
13.4TFC
33.4FM
62.1TF
312.7TFC
166TF
217.7TFC
113.9TFC

Properties (7)

additional_info
SC411827
custom_field_three
MULTIPLE CRACKS
custom_field_two
2
customer
1
datetime
2020-09-01T22:10:51-07:00
documentation
PROPIPE
is_lateral_inspection
false