Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 2, 2020, 05:27 AM
  • 08 0486_08 0485 _09012020_223738.mp4

Date
09/01/2020
W/O
845648
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00019
PipeID
P00544
Time
10:27 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8014
Sewer Name
SEPULVEDA-FIGUEROA STREET CONNECTING TRUNK
City
CARSON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
13
Purpose
Routine Assessment
Project
WO_845648_TV08028_AUG2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
36 in.
Upstream MH
08 0486
Downstream MH
08 0485
Dir. of Survey
Downstream
Length Surveyed
224.6 ft.
Total Length
224.6 ft.
Structural Index
4
Structural Quick
4131
Structural Rating
7
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
7
Pipe schematic from manhole 08 0486 to 08 0485
MH: 08 0486MH: 08 0485downstream0 ft. MWM - Water Mark, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08 04860 ft. MWL - Water Level, 5 %of cross sectional area2.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start30.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"41.5 ft. FM - Fracture Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES82.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"125.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"179.8 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"224.6 ft. AMH - Downstream Manhole, Survey Ends - 08 0485224.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (2)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.8 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES

    41.5 ft. - Fracture Multiple, from 09 to 02 o'clock, within 8 inches of joint: YES

Observations (11)

DistanceCodeObservation
2.8CM
82.1TFC
0MWM
224.6AMH08 0485
224.6CM
125.8TF
0AMH08 0486
0MWL
41.5FM
179.8TFC
30.4TFC

Properties (7)

additional_info
SC411827
custom_field_three
MULTIPLE CRACKS
custom_field_two
2
customer
1
datetime
2020-09-01T22:27:09-07:00
documentation
PROPIPE
is_lateral_inspection
false