Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 1, 2020, 05:43 AM
  • 08 0480_08 0479_08312020_231916.mp4

Date
08/31/2020
W/O
844358
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00007
PipeID
P00538
Time
10:43 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8012
Sewer Name
FRAMPTON AVENUE TRUNK
City
HARBOR CITY
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
16
Purpose
Routine Assessment
Project
WO_844358_TV08086_AUG2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
36 in.
Upstream MH
08 0480
Downstream MH
08 0479
Dir. of Survey
Downstream
Length Surveyed
188.4 ft.
Total Length
188.4 ft.
Structural Index
3
Structural Quick
3F21
Structural Rating
104
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
104
Pipe schematic from manhole 08 0480 to 08 0479
MH: 08 0480MH: 08 0479downstream0 ft. MGO - General Observation - CONNECTION IN MH, 3 O' CLOCK capped0 ft. MWM - Water Mark, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08 04800 ft. MWL - Water Level, 5 %of cross sectional area12.2 ft. CL - Crack Longitudinal, at 04 o'clock, within 8 inches of joint: YES16.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start24.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"74.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"128.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"133.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"173.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"188.4 ft. AMH - Downstream Manhole, Survey Ends - 08 0479188.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (2)

  • Crack Longitudinal, at 04 o'clock, within 8 inches of joint: YES

    12.2 ft. - Crack Longitudinal, at 04 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    16.9 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
0MGOCONNECTION IN MH, 3 O' CLOCK capped
0MWM
173.2TFC
74.3TF
12.2CL
133.2TFC
16.9CM
188.4AMH08 0479
24.4TFC
128.1TFC
188.4CM
0AMH08 0480
0MWL

Properties (7)

additional_info
SC411825
custom_field_three
multiple cracks
custom_field_two
2
customer
1
datetime
2020-08-31T22:43:16-07:00
documentation
PROPIPE
is_lateral_inspection
false