Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 4, 2020, 08:41 AM
  • 29 0114_29 0113_09042020_022849.mp4

Date
09/04/2020
W/O
844696
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00273
PipeID
P23901
Time
1:41 AM
Certificate
U-109-7948
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7335
Sewer Name
33RD STREET SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
01
Purpose
Routine Assessment
Project
RFIR_WO_844696_TV29102_AUG2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0113
Downstream MH
29 0114
Dir. of Survey
Upstream
Length Surveyed
225.2 ft.
Total Length
225.2 ft.
Structural Index
4
Structural Quick
4100
Structural Rating
4
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
4
Pipe schematic from manhole 29 0113 to 29 0114
MH: 29 0113MH: 29 0114upstream0 ft. ACOM - Cleanout Mainline, Survey Ends - 29 01140 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"1.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"12.6 ft. TBB - Tap Break-In Abandoned, at 02 o'clock, -, within 8 inches of joint: NO, 4"15.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"63.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"64.2 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"90.3 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"117.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"168.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"170.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"216.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"217.9 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES218.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"225.2 ft. AMH - Downstream Manhole, Survey Begins - 29 0113225.2 ft. MWM - Water Mark, 25 %of cross sectional area225.2 ft. MGO - General Observation - COCKROACHES IN MANHOLE225.2 ft. MWL - Water Level, 5 %of cross sectional area

Observation photos (2)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    7.3 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Tap Break-In Abandoned, at 02 o'clock, -, within 8 inches of joint: NO, 4"

    212.6 ft. - Tap Break-In Abandoned, at 02 o'clock, -, within 8 inches of joint: NO, 4"

Observations (19)

DistanceCodeObservation
0AMH29 0113
225.2ACOM29 0114
212.6TBB
221.2TFC
54.4TF
225.2TF
209.6TFC
161.3TFC
8.9TF
0MWM
7.3FM
161TBA
0MGOCOCKROACHES IN MANHOLE
6.5TF
134.9TFA
223.3TFC
107.9TF
0MWL
57TF

Properties (7)

additional_info
SC411333
custom_field_three
MULTIPLE FRACTURES
custom_field_two
3
customer
1
datetime
2020-09-04T01:41:54-07:00
documentation
PRO PIPE
is_lateral_inspection
false