Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 8, 2020, 04:28 PM
  • 29 0104_29 0103_09082020_095114.mp4

Date
09/08/2020
W/O
844696
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00273
PipeID
P23887
Time
9:28 AM
Certificate
U-109-7948
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7336
Sewer Name
33RD STREET SEWER
City
SIGNAL HILL
Loc. details
Alley
Location Code
H
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
01
Purpose
Routine Assessment
Project
RFIR_WO_844696_TV29102_AUG2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0103
Downstream MH
29 0104
Dir. of Survey
Upstream
Length Surveyed
226.6 ft.
Total Length
226.6 ft.
Structural Index
4
Structural Quick
4100
Structural Rating
4
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
6
Pipe schematic from manhole 29 0103 to 29 0104
MH: 29 0103MH: 29 0104upstream0 ft. ACOM - Cleanout Mainline, Survey Ends - 29 01046.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"8.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"17.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"20 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"34.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"71 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"94.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4"103 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4"130.2 ft. FM - Fracture Multiple, from 02 to 06 o'clock, within 8 inches of joint: YES148 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 4"169.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"172.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 4"217.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4"219.8 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: NO, 4"226.6 ft. MWM - Water Mark, 20 %of cross sectional area226.6 ft. MWL - Water Level, 15 %of cross sectional area226.6 ft. AMH - Downstream Manhole, Survey Begins - 29 0103226.6 ft. MGO - General Observation - COCKROACHES IN MH

Observation photos (2)

  • Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: NO, 4"

    6.8 ft. - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: NO, 4"

  • Fracture Multiple, from 02 to 06 o'clock, within 8 inches of joint: YES

    96.4 ft. - Fracture Multiple, from 02 to 06 o'clock, within 8 inches of joint: YES

Observations (19)

DistanceCodeObservation
217.9TFC
0MWM
6.8TFD
132.1TF
0MWL
57TF
220.5TFC
96.4FM
206.6TFC
78.6TB
0AMH29 0103
191.7TF
0MGOCOCKROACHES IN MH
53.9TFC
226.6ACOM29 0104
209.3TF
123.6TF
155.6TF
9TF

Properties (7)

additional_info
SC411334
custom_field_three
LIGHT GREASE
custom_field_two
3
customer
1
datetime
2020-09-08T09:28:19-07:00
documentation
PRO PIPE
is_lateral_inspection
false