Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 21, 2020, 08:23 AM
  • 02 1146_02 1145_9212020_014842.mp4

Date
09/21/2020
W/O
0849658
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00351
PipeID
P02930
Time
1:23 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1568
Sewer Name
02 GARFIELD AVENUE EXTENSION TRUNK
City
MONTEBELLO
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
13
Purpose
Maintenance Related
Project
20200921MDM_GARFIELD_AVENUE_EXTENSION_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
02 1146
Downstream MH
02 1145
Dir. of Survey
Downstream
Length Surveyed
320.9 ft.
Total Length
320.9 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 02 1146 to 02 1145
MH: 02 1146MH: 02 1145downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active0 ft. AMH - Upstream Manhole, Survey Begins - 1:55AM0 ft. MWM - Water Mark, 30 %of cross sectional area232.6 ft. MGO - General Observation - GREASE AT 3% OR LESS THROUGHPUT REACH320.5 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Capped320.5 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Capped320.9 ft. AMH - Downstream Manhole, Survey Ends - 1:15AM

Observation photos (1)

  • General Observation - GREASE AT 3% OR LESS THROUGHPUT REACH

    232.6 ft. - General Observation - GREASE AT 3% OR LESS THROUGHPUT REACH

Observations (8)

DistanceCodeObservation
320.9AMH1:15AM
320.5MGOConn. @ Mh, 3 O' Clock. Capped
0MWL
0MGOConn. @ Mh, 3 O' Clock. Active
0AMH1:55AM
320.5MGOConn. @ Mh, 9 O' Clock. Capped
232.6MGOGREASE AT 3% OR LESS THROUGHPUT REACH
0MWM

Properties (5)

additional_info
POST CLEANING EVALUATION ONLY
customer
LACSD
datetime
2020-09-21T01:23:30-07:00
documentation
MARTIN,OLIVER 111,CASTILLO
is_lateral_inspection
false