C 0089_C 0088_9152020_014424.mp4
66.4 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE
124.1 ft. - Surface Aggregate Visible, from 01 to 02 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC
210.3 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: NO, Start - VERY SEVERE AGG SPORATIC
247.6 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG VERY SPORATIC
831.8 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE UNDER MAG COAT
962.9 ft. - General Observation - 70% MAG COAT START
986.6 ft. - Surface Aggregate Visible, from 09 to 11 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC
1190.3 ft. - General Observation - DEBRIE ON CABLE
| Distance | Code | Observation |
|---|---|---|
| 962.9 | MGO | 70% MAG COAT START |
| 205.8 | SAV | SEVERE AGG SPORATIC |
| 2 | SSS | BLISTERING PEELING CONCRETE |
| 66.4 | SSS | BLISTERING PEELING CONCRETE |
| 1190.3 | SAV | SEVERE AGG VERY SPORATIC |
| 247.6 | SAV | SEVERE AGG VERY SPORATIC |
| 2 | MGO | MAG COAT 80% START 9:00 TO 3:00 |
| 0 | AMH | 1:55AM |
| 0 | MWL | — |
| 1190.8 | AMH | 3:35AM |
| 210.3 | SAV | VERY SEVERE AGG SPORATIC |
| 831.8 | SSS | BLISTERING PEELING CONCRETE UNDER MAG COAT |
| 986.6 | SAV | SEVERE AGG SPORATIC |
| 1190.3 | MGO | 70% MAG COAT FINISH |
| 124.1 | SAV | SEVERE AGG SPORATIC |
| 1190.3 | SSS | BLISTERING PEELING CONCRETE |
| 15.5 | SSS | BLISTERING PEELING CONCRETE |
| 0 | MWM | — |
| 1190.3 | MGO | DEBRIE ON CABLE |