- Date
- 09/08/2020
- W/O
- 844360
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00221
- PipeID
- P01836
- Time
- 4:34 AM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K8027
- Sewer Name
- VERNON EXTENSION TRUNK
- City
- VERNON
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 04
- Purpose
- Routine Assessment
- Project
- RFIR_WO_844360_TV01271_AUG2020
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 24 in.
- Width
- 30 in.
- Upstream MH
- 01 0995A
- Downstream MH
- 01 0995
- Dir. of Survey
- Downstream
- Length Surveyed
- 314 ft.
- Total Length
- 314 ft.
- Structural Index
- 2
- Structural Quick
- 3K2I
- Structural Rating
- 295
- O&M Index
- 2
- O&M Quick
- 2K00
- O&M Rating
- 124
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 419
Pipe schematic from manhole 01 0995A to 01 0995 Observation photos (3)

6 ft. - Material Change, Cast Iron/RCP

6 ft. - Surface Roughness Increased, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

59.3 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start