Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 22, 2016, 03:31 PM
  • 29 0540_29 0539_7222016_083734.mp4

Date
07/22/2016
W/O
0579968
Weather
Very Dry
Operator/Surveyor
MIRANDA
Sewer ID
Z00537
PipeID
P24618
Time
8:31 AM
Certificate
U-1014-06022542
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7186
Sewer Name
29 21ST STREET SEWER
City
SIGNAL HILL
Loc. details
Other
Location Code
Z
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
03
Purpose
Routine Assessment
Project
20160721AM_21ST_STREET_SEWER
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Upstream MH
29 0539
Downstream MH
29 0540
Dir. of Survey
Upstream
Length Surveyed
357.1 ft.
Total Length
357.1 ft.
Structural Index
3
Structural Quick
5845
Structural Rating
102
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
102
Pipe schematic from manhole 29 0539 to 29 0540
MH: 29 0539MH: 29 0540upstream0 ft. AMH - Upstream Manhole, Survey Ends - 9:42 AM0.8 ft. MGO - General Observation - ROACHES INSIDE THE MH.1.1 ft. MGO - General Observation - OPEN JOINTS THROUGHOUT THE REACH1.8 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish1.8 ft. MGO - General Observation - SLIGHT GREASE/DEBRIS THROUGHOUT THE REACH1.8 ft. MGO - General Observation - BROKEN PIPE THROUGHOUT THE REACH1.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish5.6 ft. MGO - General Observation - CHIPPING17.9 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish19.4 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6"26.9 ft. CL - Crack Longitudinal, at 06 o'clock, within 8 inches of joint: YES, Finish26.9 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start29.9 ft. CL - Crack Longitudinal, at 06 o'clock, within 8 inches of joint: YES, Start33 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish45.6 ft. B - Broken, from 10 to 04 o'clock, within 8 inches of joint: YES56.2 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start79.6 ft. JSL - Joint Separated Large79.6 ft. B - Broken, from 10 to 03 o'clock, within 8 inches of joint: YES83 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish83 ft. FL - Fracture Longitudinal, at 06 o'clock, within 8 inches of joint: YES, Finish95.4 ft. FL - Fracture Longitudinal, at 06 o'clock, within 8 inches of joint: YES, Start98.7 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start98.7 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish103.1 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start121.5 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6"138.3 ft. FL - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES - POSSIBLY BROKEN178.8 ft. B - Broken, at 12 o'clock, within 8 inches of joint: YES185.1 ft. B - Broken, from 10 to 02 o'clock, within 8 inches of joint: YES191.1 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish191.1 ft. FL - Fracture Longitudinal, at 06 o'clock, within 8 inches of joint: YES, Finish214.3 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start214.3 ft. FL - Fracture Longitudinal, at 06 o'clock, within 8 inches of joint: YES, Start220.5 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6"237.5 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start240.6 ft. B - Broken, from 04 to 08 o'clock, within 8 inches of joint: YES249.9 ft. FM - Fracture Multiple, from 10 to 12 o'clock, within 8 inches of joint: YES266.7 ft. TB - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: NO, 6" - OPEN271.7 ft. FL - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES277.9 ft. B - Broken, from 08 to 02 o'clock, within 8 inches of joint: YES284.1 ft. B - Broken, from 08 to 04 o'clock, within 8 inches of joint: YES293.6 ft. JSM - Joint Separated Medium293.6 ft. FM - Fracture Multiple, from 11 to 02 o'clock, within 8 inches of joint: YES - POSSIBLY BROKEN301.9 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 4" - OPEN302.1 ft. JOL - Joint Offset Large309 ft. FM - Fracture Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES319.7 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6"320.8 ft. JSM - Joint Separated Medium320.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start327 ft. JSM - Joint Separated Medium333.1 ft. B - Broken, from 11 to 03 o'clock, within 8 inches of joint: YES345.7 ft. FM - Fracture Multiple, from 06 to 04 o'clock, within 8 inches of joint: YES - POSSIBLY BROKEN348.7 ft. FL - Fracture Longitudinal, at 04 o'clock, within 8 inches of joint: YES353.1 ft. MGO - General Observation - BROKEN PIPE353.1 ft. B - Broken, from 04 to 08 o'clock, within 8 inches of joint: YES353.1 ft. MGO - General Observation - BROKEN PIPE357.1 ft. MWL - Water Level, 5 %of cross sectional area - STAGNANT WATER/DRY LINE357.1 ft. AMH - Downstream Manhole, Survey Begins - 8:36 AM357.1 ft. MGO - General Observation - ROACHES INSIDE THE MH.

Observation photos (29)

  • General Observation - BROKEN PIPE

    4 ft. - General Observation - BROKEN PIPE

  • Broken, from 04 to 08 o'clock, within 8 inches of joint: YES

    4 ft. - Broken, from 04 to 08 o'clock, within 8 inches of joint: YES

  • General Observation - BROKEN PIPE

    4 ft. - General Observation - BROKEN PIPE

  • Fracture Longitudinal, at 04 o'clock, within 8 inches of joint: YES

    8.4 ft. - Fracture Longitudinal, at 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 06 to 04 o'clock, within 8 inches of joint: YES - POSSIBLY BROKEN

    11.4 ft. - Fracture Multiple, from 06 to 04 o'clock, within 8 inches of joint: YES - POSSIBLY BROKEN

  • Broken, from 11 to 03 o'clock, within 8 inches of joint: YES

    24 ft. - Broken, from 11 to 03 o'clock, within 8 inches of joint: YES

  • Joint Separated Medium

    30.1 ft. - Joint Separated Medium

  • Joint Separated Medium

    36.3 ft. - Joint Separated Medium

  • Fracture Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES

    48.1 ft. - Fracture Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES

  • Joint Offset Large

    55 ft. - Joint Offset Large

  • Joint Separated Medium

    63.5 ft. - Joint Separated Medium

  • Fracture Multiple, from 11 to 02 o'clock, within 8 inches of joint: YES - POSSIBLY BROKEN

    63.5 ft. - Fracture Multiple, from 11 to 02 o'clock, within 8 inches of joint: YES - POSSIBLY BROKEN

  • Broken, from 08 to 04 o'clock, within 8 inches of joint: YES

    73 ft. - Broken, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Broken, from 08 to 02 o'clock, within 8 inches of joint: YES

    79.2 ft. - Broken, from 08 to 02 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES

    85.4 ft. - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 10 to 12 o'clock, within 8 inches of joint: YES

    107.2 ft. - Fracture Multiple, from 10 to 12 o'clock, within 8 inches of joint: YES

  • Broken, from 04 to 08 o'clock, within 8 inches of joint: YES

    116.5 ft. - Broken, from 04 to 08 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    119.6 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    142.8 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 06 o'clock, within 8 inches of joint: YES, Start

    142.8 ft. - Fracture Longitudinal, at 06 o'clock, within 8 inches of joint: YES, Start

  • Broken, from 10 to 02 o'clock, within 8 inches of joint: YES

    172 ft. - Broken, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Broken, at 12 o'clock, within 8 inches of joint: YES

    178.3 ft. - Broken, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES - POSSIBLY BROKEN

    218.8 ft. - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES - POSSIBLY BROKEN

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    258.4 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 06 o'clock, within 8 inches of joint: YES, Start

    261.7 ft. - Fracture Longitudinal, at 06 o'clock, within 8 inches of joint: YES, Start

  • Joint Separated Large

    277.5 ft. - Joint Separated Large

  • Broken, from 10 to 03 o'clock, within 8 inches of joint: YES

    277.5 ft. - Broken, from 10 to 03 o'clock, within 8 inches of joint: YES

  • Broken, from 10 to 04 o'clock, within 8 inches of joint: YES

    311.5 ft. - Broken, from 10 to 04 o'clock, within 8 inches of joint: YES

  • General Observation - CHIPPING

    351.5 ft. - General Observation - CHIPPING

Observations (58)

DistanceCodeObservation
355.3FM
11.4FMPOSSIBLY BROKEN
73B
337.7TFC
24B
85.4FL
166FL
357.1AMH9:42 AM
48.1FM
356.3MGOROACHES INSIDE THE MH.
311.5B
300.9CL
55.2TFOPEN
116.5B
136.6TFC
355.3MGOSLIGHT GREASE/DEBRIS THROUGHOUT THE REACH
0MWLSTAGNANT WATER/DRY LINE
258.4FL
63.5JSM
36.3JSM
172B
356MGOOPEN JOINTS THROUGHOUT THE REACH
37.4TFC
107.2FM
258.4CL
79.2B
4MGOBROKEN PIPE
274.1FL
218.8FLPOSSIBLY BROKEN
330.2CL
63.5FMPOSSIBLY BROKEN
235.6TFC
0AMH8:36 AM
330.2CL
4B
142.8FL
355.3MGOBROKEN PIPE THROUGHOUT THE REACH
119.6FM
0MGOROACHES INSIDE THE MH.
36.3CM
355.3CM
166FL
277.5JSL
324.1CL
277.5B
254CL
178.3B
274.1FL
90.4TBOPEN
327.2CL
4MGOBROKEN PIPE
339.2CL
8.4FL
55JOL
351.5MGOCHIPPING
30.1JSM
142.8FL
261.7FL

Properties (6)

custom_field_three
BROKEN PIPE THROUGHOUT THE REACH
custom_field_two
1
customer
LACSD
datetime
2016-07-22T08:31:39-07:00
documentation
MIRANDA, FRANKLIN, SHADLER
is_lateral_inspection
false