Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 20, 2016, 10:17 AM
  • 02 1723_02 1722_7202016_035643.mp4

Date
07/20/2016
W/O
0580148
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00289
PipeID
P18887
Time
3:17 AM
Certificate
U-104-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0195
Sewer Name
02 MONTEREY PARK EXTENSION TRUNK
City
MONTEREY PARK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
07
Purpose
Capital Improvement Program Assesment
Project
20160720MDM_MONTEREY_PARK_EXTENSION_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Upstream MH
02 1723
Downstream MH
02 1722
Dir. of Survey
Downstream
Length Surveyed
362.8 ft.
Total Length
362.8 ft.
Structural Index
3
Structural Quick
3C27
Structural Rating
68
O&M Index
3
O&M Quick
5142
O&M Rating
28
Overall Index
3
Overall Quick
Overall Rating
96
Pipe schematic from manhole 02 1723 to 02 1722
MH: 02 1723MH: 02 1722downstream0 ft. MWM - Water Mark, 80 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active0 ft. MWL - Water Level, 60 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 6 O' Clock. Active0 ft. AMH - Upstream Manhole, Survey Begins - 4:00AM0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Start8.3 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Change - HAIRLINE8.3 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SLIGHT12 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES, Start - SLIGHT12 ft. MWL - Water Level, 20 %of cross sectional area12 ft. FC - Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES - SLIGHT12 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, - HAIRLINE12 ft. MWM - Water Mark, 50 %of cross sectional area12 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Finish12 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start15.7 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - SLIGHT18.9 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES, Start - SLIGHT18.9 ft. MWL - Water Level, 10 %of cross sectional area18.9 ft. MWM - Water Mark, 30 %of cross sectional area22.5 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES, Finish - SLIGHT22.5 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES, Finish - SLIGHT22.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish22.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start73.1 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open80.6 ft. FL - Fracture Longitudinal, at 04 o'clock, within 8 inches of joint: YES - HAIRLINE92.4 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES - H107.8 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - H112.2 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H120.5 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - H120.5 ft. IS - Infiltration Stain, at 10 o'clock, within 8 inches of joint: YES124.9 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open127.7 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H144.6 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open191.7 ft. DSGV - Deposits Settled Gravel, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES200.2 ft. IW - Infiltration Weeper, from 08 to 10 o'clock, within 8 inches of joint: YES233.8 ft. IR - Infiltration Runner, from 08 to 10 o'clock, within 8 inches of joint: YES239.4 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 10 o'clock, , within 8 inches of joint: YES239.4 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Open268.8 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H282.2 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Active292 ft. FS - Fracture Spiral, from 08 to 10 o'clock, within 8 inches of joint: YES, Start - SLIGHT297.1 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - H300.1 ft. FS - Fracture Spiral, from 02 to 04 o'clock, within 8 inches of joint: YES, Start - SLIGHT308.8 ft. FS - Fracture Spiral, from 02 to 04 o'clock, within 8 inches of joint: YES, Finish - SLIGHT308.8 ft. FS - Fracture Spiral, from 08 to 10 o'clock, within 8 inches of joint: YES, Finish - SLIGHT308.8 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H311.9 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - H313.7 ft. FS - Fracture Spiral, from 02 to 04 o'clock, within 8 inches of joint: YES, Start - SLIGHT313.7 ft. FS - Fracture Spiral, from 08 to 11 o'clock, within 8 inches of joint: YES, Start - SLIGHT315.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H315.8 ft. IS - Infiltration Stain, from 09 to 12 o'clock, within 8 inches of joint: YES324.9 ft. FS - Fracture Spiral, from 02 to 04 o'clock, within 8 inches of joint: YES - SLIGHT324.9 ft. FS - Fracture Spiral, from 09 to 11 o'clock, within 8 inches of joint: YES - SLIGHT332.9 ft. ID - Infiltration Dripper, from 09 to 11 o'clock, within 8 inches of joint: YES346.4 ft. FS - Fracture Spiral, from 08 to 11 o'clock, within 8 inches of joint: YES, Finish - SLIGHT346.4 ft. FS - Fracture Spiral, from 02 to 04 o'clock, within 8 inches of joint: YES, Finish - SLIGHT350.5 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - Active350.5 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H362.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish362.2 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active362.8 ft. AMH - Downstream Manhole, Survey Ends - 5:25AM

Observation photos (19)

  • Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Change - HAIRLINE

    8.3 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Change - HAIRLINE

  • Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES, Start - SLIGHT

    12 ft. - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES, Start - SLIGHT

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES,  - HAIRLINE

    12 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, - HAIRLINE

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    12 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES, Start - SLIGHT

    18.9 ft. - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES, Start - SLIGHT

  • Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES, Finish - SLIGHT

    22.5 ft. - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES, Finish - SLIGHT

  • Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES, Finish - SLIGHT

    22.5 ft. - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES, Finish - SLIGHT

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    22.5 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 04 o'clock, within 8 inches of joint: YES - HAIRLINE

    80.6 ft. - Fracture Longitudinal, at 04 o'clock, within 8 inches of joint: YES - HAIRLINE

  • Infiltration Stain, at 10 o'clock, within 8 inches of joint: YES

    120.5 ft. - Infiltration Stain, at 10 o'clock, within 8 inches of joint: YES

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 10 o'clock,  , within 8 inches of joint: YES

    239.4 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 10 o'clock, , within 8 inches of joint: YES

  • Fracture Spiral, from 08 to 10 o'clock, within 8 inches of joint: YES, Start - SLIGHT

    292 ft. - Fracture Spiral, from 08 to 10 o'clock, within 8 inches of joint: YES, Start - SLIGHT

  • Fracture Spiral, from 02 to 04 o'clock, within 8 inches of joint: YES, Start - SLIGHT

    300.1 ft. - Fracture Spiral, from 02 to 04 o'clock, within 8 inches of joint: YES, Start - SLIGHT

  • Fracture Spiral, from 02 to 04 o'clock, within 8 inches of joint: YES, Start - SLIGHT

    313.7 ft. - Fracture Spiral, from 02 to 04 o'clock, within 8 inches of joint: YES, Start - SLIGHT

  • Fracture Spiral, from 08 to 11 o'clock, within 8 inches of joint: YES, Start - SLIGHT

    313.7 ft. - Fracture Spiral, from 08 to 11 o'clock, within 8 inches of joint: YES, Start - SLIGHT

  • Infiltration Stain, from 09 to 12 o'clock, within 8 inches of joint: YES

    315.8 ft. - Infiltration Stain, from 09 to 12 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 02 to 04 o'clock, within 8 inches of joint: YES - SLIGHT

    324.9 ft. - Fracture Spiral, from 02 to 04 o'clock, within 8 inches of joint: YES - SLIGHT

  • Fracture Spiral, from 09 to 11 o'clock, within 8 inches of joint: YES - SLIGHT

    324.9 ft. - Fracture Spiral, from 09 to 11 o'clock, within 8 inches of joint: YES - SLIGHT

Observations (62)

DistanceCodeObservation
22.5FLSLIGHT
2DAGS
297.1FCH
18.9FLSLIGHT
362.2FL
0MWM
324.9FSSLIGHT
92.4FLH
80.6FLHAIRLINE
18.9MWL
124.9TFOpen
362.2MGOConn. @ Mh, 9 O' Clock. Active
0MGOConn. @ Mh, 3 O' Clock. Active
0MWL
346.4FSSLIGHT
346.4FSSLIGHT
308.8FSSLIGHT
239.4DAE
0MGOConn. @ Mh, 6 O' Clock. Active
15.7FCSLIGHT
308.8FSSLIGHT
12FLSLIGHT
300.1FSSLIGHT
362.8AMH5:25AM
292FSSLIGHT
120.5FLH
324.9FSSLIGHT
268.8FLH
22.5FLSLIGHT
0AMH4:00AM
350.5TFActive
332.9ID
0MGOConn. @ Mh, 9 O' Clock. Active
282.2TFActive
233.8IR
191.7DSGV
12MWL
144.6TFOpen
239.4TFOpen
12FCSLIGHT
315.8FLH
112.2FLH
127.7FLH
22.5DAGS
12FLHAIRLINE
200.2IW
107.8FCH
350.5FLH
8.3FLHAIRLINE
120.5IS
313.7FSSLIGHT
22.5DAGS
313.7FSSLIGHT
12MWM
12DAGS
315.8IS
12DAGS
311.9FCH
8.3FCSLIGHT
18.9MWM
308.8FCH
73.1TFOpen

Properties (6)

custom_field_three
SLIGHT SPIRAL FRACTURES JOINT TO JOINT LONGER
custom_field_two
2
customer
LACSD
datetime
2016-07-20T03:17:41-07:00
documentation
MARTIN,MANANES,REVELES,OLIVER 111
is_lateral_inspection
false