Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 15, 2016, 07:47 AM
  • B 1284_B 1283_7152016_012011.mp4

Date
07/15/2016
W/O
0574360
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z01126
PipeID
P25179
Time
12:47 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0187
Sewer Name
B JOINT OUTFALL B - UNIT 6J
City
PASADENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 16
Page No.
12
Purpose
Routine Assessment
Project
20160715MDM_JOINT_OUTFALL_B_UNIT_6J
Material
NRCP
Shape
Circular
Height
18 in.
Upstream MH
B 1284
Downstream MH
B 1283
Dir. of Survey
Downstream
Length Surveyed
160.6 ft.
Total Length
160.6 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole B 1284 to B 1283
MH: B 1284MH: B 1283downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MGO - General Observation - APPEARS BRIDGE BEING BUILT OVER OUR LINE0 ft. AMH - Upstream Manhole, Survey Begins - 12:50AM0 ft. MGO - General Observation - LARGE SECTION OF HILL DUGOUT BESIDE PIPE8 ft. MGO - General Observation - 18" NRCP-CIPP160.6 ft. AMH - Downstream Manhole, Survey Ends - 1:10AM

Observation photos (1)

  • General Observation - 18" NRCP-CIPP

    8 ft. - General Observation - 18" NRCP-CIPP

Observations (7)

DistanceCodeObservation
0MWL
160.6AMH1:10AM
8MGO18" NRCP-CIPP
0MWM
0MGOAPPEARS BRIDGE BEING BUILT OVER OUR LINE
0AMH12:50AM
0MGOLARGE SECTION OF HILL DUGOUT BESIDE PIPE

Properties (7)

custom_field_three
CIPP LINER
custom_field_two
4
customer
LACSD
datetime
2016-07-15T00:47:53-07:00
documentation
MARTIN,MANANES,REVELES,OLIVER 111
is_lateral_inspection
false
lining
CIPP