Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 14, 2016, 07:42 AM
  • G 0146_G 0145_7142016_024712.mp4

Date
07/14/2016
W/O
0580099
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z01180
PipeID
P01469
Time
12:42 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
HO185
Sewer Name
G JOINT OUTFALL G - UNIT 8
City
COMPTON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
16
Purpose
Capital Improvement Program Assesment
Project
20160709MDM_JOINT_OUTFALL_G_UNIT_8
Material
RCP-CTL
Shape
Circular
Height
36 in.
Upstream MH
G 0146
Downstream MH
G 0145
Dir. of Survey
Downstream
Length Surveyed
132.6 ft.
Total Length
132.6 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
5
O&M Quick
5100
O&M Rating
5
Overall Index
4
Overall Quick
Overall Rating
11
Pipe schematic from manhole G 0146 to G 0145
MH: G 0146MH: G 0145downstream0 ft. AMH - Upstream Manhole, Survey Begins - 1:45AM0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Capped0 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Capped0 ft. MWM - Water Mark, 80 %of cross sectional area0 ft. MWL - Water Level, 50 %of cross sectional area2 ft. MGO - General Observation - TILES 90% IN PLACE3.1 ft. MGO - General Observation - 2 MISSING TILES 11:003.1 ft. SAV - Surface Aggregate Visible, at 11 o'clock, within 8 inches of joint: YES - SEVERE AG AREA MISSING TILE6.1 ft. MGO - General Observation - 1 MISSING TILE 12:0022.4 ft. MGO - General Observation - MISSING TILES 10% START 10:00 TO 2:0050.9 ft. SAV - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG AREAS MISSING TILES63.6 ft. MGO - General Observation - 30% MISSIG TILES93.8 ft. MGO - General Observation - 60% MISSING TILES START107.9 ft. MGO - General Observation - 60% MISSING TILES FINISH132.3 ft. SAV - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG AREAS MISSING TILES132.3 ft. MGO - General Observation - MISSING TILES 10% FINISH132.3 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Capped132.6 ft. AMH - Downstream Manhole, Survey Ends - 2:10AM

Observation photos (8)

  • General Observation - TILES 90% IN PLACE

    2 ft. - General Observation - TILES 90% IN PLACE

  • General Observation - 2 MISSING TILES 11:00

    3.1 ft. - General Observation - 2 MISSING TILES 11:00

  • Surface Aggregate Visible, at 11 o'clock, within 8 inches of joint: YES - SEVERE AG AREA MISSING TILE

    3.1 ft. - Surface Aggregate Visible, at 11 o'clock, within 8 inches of joint: YES - SEVERE AG AREA MISSING TILE

  • General Observation - 1 MISSING TILE 12:00

    6.1 ft. - General Observation - 1 MISSING TILE 12:00

  • General Observation - MISSING TILES 10% START 10:00 TO 2:00

    22.4 ft. - General Observation - MISSING TILES 10% START 10:00 TO 2:00

  • Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG AREAS MISSING TILES

    50.9 ft. - Surface Aggregate Visible, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG AREAS MISSING TILES

  • General Observation - 30% MISSIG TILES

    63.6 ft. - General Observation - 30% MISSIG TILES

  • General Observation - 60% MISSING TILES START

    93.8 ft. - General Observation - 60% MISSING TILES START

Observations (18)

DistanceCodeObservation
0AMH1:45AM
132.3SAVSEVERE AGG AREAS MISSING TILES
0MGOConn. @ Mh, 3 O' Clock. Capped
3.1MGO2 MISSING TILES 11:00
93.8MGO60% MISSING TILES START
107.9MGO60% MISSING TILES FINISH
6.1MGO1 MISSING TILE 12:00
0MGOConn. @ Mh, 9 O' Clock. Capped
3.1SAVSEVERE AG AREA MISSING TILE
132.3MGOMISSING TILES 10% FINISH
63.6MGO30% MISSIG TILES
50.9SAVSEVERE AGG AREAS MISSING TILES
0MWM
132.3MGOConn. @ Mh, 9 O' Clock. Capped
0MWL
2MGOTILES 90% IN PLACE
22.4MGOMISSING TILES 10% START 10:00 TO 2:00
132.6AMH2:10AM

Properties (6)

custom_field_three
10% TO 60% MISSING TILES
custom_field_two
3
customer
LACSD
datetime
2016-07-14T00:42:35-07:00
documentation
MARTIN,MANANES,REVELES,OLIVER 111
is_lateral_inspection
false