Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 2, 2016, 12:57 PM
Date
07/02/2016
W/O
0574371
Weather
Dry
Operator/Surveyor
REVELES
Sewer ID
Z01106
PipeID
P24586
Time
5:57 AM
Certificate
U-115-06022630
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G6731
Sewer Name
29 19TH STREET SEWER
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
03
Purpose
Routine Assessment
Project
20160702VMR_19TH_STREET_SEWER
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
29 0531
Downstream MH
29 0530
Dir. of Survey
Downstream
Length Surveyed
275.5 ft.
Total Length
275.5 ft.
Structural Index
2
Structural Quick
332A
Structural Rating
34
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
38
Pipe schematic from manhole 29 0531 to 29 0530
MH: 29 0531MH: 29 0530downstream0 ft. MWM - Water Mark, 5 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 6:03 AM4 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES14.7 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: YES, 4" - ACTIVE16.2 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES31.6 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES34.3 ft. CC - Crack Circumferential, from 10 to 12 o'clock, within 8 inches of joint: YES38 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4" - ACTIVE40.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4"42.6 ft. CS - Crack Spiral, from 10 to 01 o'clock, within 8 inches of joint: YES46.2 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES49 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES60.8 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES64 ft. CL - Crack Longitudinal, at 02 o'clock, within 8 inches of joint: YES69.6 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES69.6 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES73.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4" - OPEN73.9 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES74.9 ft. CS - Crack Spiral, from 10 to 01 o'clock, within 8 inches of joint: YES81.3 ft. CM - Crack Multiple, from 11 to 01 o'clock, within 8 inches of joint: YES91.1 ft. TFB - Tap Factory Made Abandoned, at 02 o'clock, -, within 8 inches of joint: YES, 4" - OPEN120.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4" - OPEN128.4 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES141.2 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 4" - OPEN165.1 ft. TFI - Tap Factory Made Intruding, at 11 o'clock, -, -, within 8 inches of joint: YES, 4", 1" - OPEN192 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4" - OPEN206.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4" - OPEN241.5 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES242.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4" - OPEN275.1 ft. TF - Tap Factory Made, at 09 o'clock, -, within 8 inches of joint: NO, 4" - OPEN275.3 ft. MGO - General Observation - MULTIPLE CRACKS AT 90% OF JOINTS275.5 ft. AMH - Downstream Manhole, Survey Ends - 07:54 AM

Observation photos (5)

  • Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4"

    40.8 ft. - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 4"

  • Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    128.4 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 4" - OPEN

    141.2 ft. - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 4" - OPEN

  • Tap Factory Made Intruding, at 11 o'clock, -, -, within 8 inches of joint: YES, 4", 1" - OPEN

    165.1 ft. - Tap Factory Made Intruding, at 11 o'clock, -, -, within 8 inches of joint: YES, 4", 1" - OPEN

  • Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    241.5 ft. - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

Observations (33)

DistanceCodeObservation
0MWM
0MWL
165.1TFIOPEN
49CL
74.9CS
275.5AMH07:54 AM
38TFACTIVE
73.5TFOPEN
34.3CC
275.3MGOMULTIPLE CRACKS AT 90% OF JOINTS
46.2CL
120.6TFOPEN
141.2TFDOPEN
14.7TFACTIVE
64CL
73.9CL
69.6CL
31.6CL
0AMH6:03 AM
16.2CL
128.4CM
91.1TFBOPEN
206.4TFOPEN
241.5CM
275.1TFOPEN
81.3CM
192TFOPEN
69.6CL
40.8TF
60.8CL
242.1TFOPEN
42.6CS
4CL

Properties (5)

custom_field_two
3
customer
LACSD
datetime
2016-07-02T05:57:08-07:00
documentation
REVELES, OLIVER III
is_lateral_inspection
false