- Date
- 08/27/2020
- W/O
- 844349
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00648
- PipeID
- P13208
- Time
- 11:30 PM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K7969
- Sewer Name
- ARROYO SECO TRUNK, SECTION 5
- City
- SOUTH PASADENA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 16
- Page No.
- 17
- Purpose
- Routine Assessment
- Project
- RFIR_WO_844349_TV16081_AUG2020
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 16 in.
- Width
- 16 in.
- Upstream MH
- 16 0175
- Downstream MH
- 16 0176
- Dir. of Survey
- Upstream
- Length Surveyed
- 319.3 ft.
- Total Length
- 319.3 ft.
- Structural Index
- 3
- Structural Quick
- 3L2L
- Structural Rating
- 315
- O&M Index
- 2
- O&M Quick
- 2L00
- O&M Rating
- 126
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 441
Pipe schematic from manhole 16 0175 to 16 0176 Observation photos (6)

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

5 ft. - Repair Patch, from 06 to 02 o'clock, within 8 inches of joint: YES - RELOCATED MH/ABANDONED MH

311.9 ft. - Material Change, Cast Iron

311.9 ft. - Surface Corrosion Metal Pipe, from 12 to 12 o'clock, within 8 inches of joint: YES, Start

318.6 ft. - General Photograph - METAL PIPE CORROSION VIEW OF U/S.

319.3 ft. - Survey Abandoned - DUE TO METAL PIPE CORROSION.