Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 2, 2020, 10:12 AM
  • 32 1302_32 1136 _07022020_031706.mp4

Date
07/02/2020
W/O
838955
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00842
PipeID
P19589
Time
3:12 AM
Certificate
U-111-11880
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7865
Sewer Name
SOLEDAD CANYON TRUNK, SECTION 5
City
SANTA CLARITA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 32
Page No.
11
Purpose
Routine Assessment
Project
WO_838955_TV32057_JUL2020
Sewer Type
Siphon
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
32 1302
Downstream MH
32 1136
Dir. of Survey
Downstream
Length Surveyed
6.9 ft.
Total Length
6.9 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
5
Pipe schematic from manhole 32 1302 to 32 1136
MH: 32 1302MH: 32 1136downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 32 13020 ft. MWM - Water Mark, 25 %of cross sectional area2 ft. CM - Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES6.9 ft. MSA - Survey Abandoned - VIEW OF DOWNLEG OF U/S SIPHON.

Observation photos (3)

  • Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES

    2 ft. - Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES

  • Survey Abandoned - VIEW OF DOWNLEG OF U/S SIPHON.

    6.9 ft. - Survey Abandoned - VIEW OF DOWNLEG OF U/S SIPHON.

Observations (6)

DistanceCodeObservation
0MWL
0AMH32 1302
2CM
0MWM
2DAGS
6.9MSAVIEW OF DOWNLEG OF U/S SIPHON.

Properties (8)

additional_info
SC411704
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2020-07-02T03:12:24-07:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
29814