Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 12, 2020, 10:05 AM
  • C 0093_C 0092_9122020_032251.mp4

Date
09/12/2020
W/O
0834128
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00122
PipeID
P09560
Time
3:05 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1563
Sewer Name
C JOINT OUTFALL C - UNIT 3C
City
LONG BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
23
Purpose
Capital Improvement Program Assesment
Project
20200910_JOINT_OUTFALL_C_UNIT_3C
Material
Reinforced Concrete Pipe
Shape
Circular
Height
60 in.
Upstream MH
C 0093
Downstream MH
C 0092
Dir. of Survey
Downstream
Length Surveyed
1025.7 ft.
Total Length
1025.7 ft.
Structural Index
4
Structural Quick
5144
Structural Rating
25
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
3
Overall Quick
Overall Rating
27
Pipe schematic from manhole C 0093 to C 0092
MH: C 0093MH: C 0092downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 3:20AM2 ft. MGO - General Observation - CONCRETE BEAM AT 12:00 MISSING SEVERE AGG AND FALLING APART2 ft. MGO - General Observation - MAG COAT 80% START 10:00 TO 2:002 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE2 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG33.3 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGGUNDER MAG COAT61.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start195 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG240.3 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - PEELING CONCRETE UNDER MAG COAT503.6 ft. MGO - General Observation - CONCRETE BEAM AT 12:00 FALLING APART538 ft. SRC - Surface Reinforcement Corroded, from 11 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR538 ft. MGO - General Observation - RECORDING ERROR ON DISC NEW TAPE # H1564691.4 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG719.5 ft. MGO - General Observation - MAG COAT 90%1025.1 ft. MGO - General Observation - MAG COAT 90% FINISH1025.1 ft. MGO - General Observation - CONCRETE BEAM AT 12:00 FALLING APART1025.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish1025.2 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG1025.2 ft. SAM - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG1025.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - BLISTERING PEELING CONCRETE1025.7 ft. AMH - Downstream Manhole, Survey Ends - 4:35AM

Observation photos (12)

  • General Observation - CONCRETE BEAM AT 12:00 MISSING SEVERE AGG AND FALLING APART

    2 ft. - General Observation - CONCRETE BEAM AT 12:00 MISSING SEVERE AGG AND FALLING APART

  • General Observation - MAG COAT 80% START 10:00 TO 2:00

    2 ft. - General Observation - MAG COAT 80% START 10:00 TO 2:00

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

  • Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGGUNDER MAG COAT

    33.3 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGGUNDER MAG COAT

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    61.8 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG

    195 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - PEELING CONCRETE UNDER MAG COAT

    240.3 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - PEELING CONCRETE UNDER MAG COAT

  • General Observation - CONCRETE BEAM AT 12:00 FALLING APART

    503.6 ft. - General Observation - CONCRETE BEAM AT 12:00 FALLING APART

  • Surface Reinforcement Corroded, from 11 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

    538 ft. - Surface Reinforcement Corroded, from 11 to 12 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

  • Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG

    691.4 ft. - Surface Aggregate Missing, from 09 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • General Observation - MAG COAT 90%

    719.5 ft. - General Observation - MAG COAT 90%

Observations (23)

DistanceCodeObservation
1025.1MGOMAG COAT 90% FINISH
719.5MGOMAG COAT 90%
195SAMSEVERE AGG
61.8DAGS
538SRCCIRCUM REBAR
2MGOCONCRETE BEAM AT 12:00 MISSING SEVERE AGG AND FALLING APART
1025.7AMH4:35AM
2MGOMAG COAT 80% START 10:00 TO 2:00
1025.2DAGS
1025.2SAMSEVERE AGG
1025.2SAMSEVERE AGG
0MWL
240.3SSSPEELING CONCRETE UNDER MAG COAT
503.6MGOCONCRETE BEAM AT 12:00 FALLING APART
691.4SAMSEVERE AGG
33.3SAMSEVERE AGGUNDER MAG COAT
538MGORECORDING ERROR ON DISC NEW TAPE # H1564
0MWM
2SSSBLISTERING PEELING CONCRETE
0AMH3:20AM
1025.2SSSBLISTERING PEELING CONCRETE
2SAMSEVERE AGG
1025.1MGOCONCRETE BEAM AT 12:00 FALLING APART

Properties (6)

custom_field_three
CIRCUM REBAR CORRODED 1 AREA -SEVERE AGG MISSING
custom_field_two
2
customer
LACSD
datetime
2020-09-12T03:05:12-07:00
documentation
MARTIN,OLIVER 111-BARR,CASTILLO
is_lateral_inspection
false