- Date
- 09/11/2020
- W/O
- 0823779
- Weather
- Dry
- Operator/Surveyor
- IGNACIO
- Sewer ID
- Z00247
- PipeID
- P04406
- Time
- 8:39 AM
- Certificate
- PENDING
- System Owner
- LACSD
- Date Cleaned
- 09/11/20
- Pre-Cleaning
- Not Known
- Media Label
- H1562
- Sewer Name
- 02 DOUGLAS AVENUE RELIEF TRUNK
- City
- EAST LOS ANGELES
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 08
- Purpose
- Capital Improvement Program Assesment
- Project
- 20200911MI_DOUGLAS_AVENUE_RELIEF_TRUNK
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 8 in.
- Upstream MH
- 02 2090
- Downstream MH
- 02 2089
- Dir. of Survey
- Downstream
- Length Surveyed
- 263.9 ft.
- Total Length
- 263.9 ft.
- Structural Index
- 2
- Structural Quick
- 3223
- Structural Rating
- 12
- O&M Index
- 3
- O&M Quick
- 4224
- O&M Rating
- 16
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 28
Pipe schematic from manhole 02 2090 to 02 2089 Observation photos (5)

37.9 ft. - Surface Spalling, from 08 to 10 o'clock, within 8 inches of joint: YES

40.8 ft. - Surface Spalling, from 08 to 10 o'clock, within 8 inches of joint: YES

89.3 ft. - General Observation - SPALLING/CHIPPING 3 OCLOCK, THROUGHOUT THE REACH

263.8 ft. - Deposits Settled Compacted, 25 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO - AT MH 2089

263.9 ft. - Upstream Manhole, Survey Ends - 10:30 AM