Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 30, 2020, 07:25 AM
  • C 0335_C 0334_07302020_004935.mp4

Date
07/30/2020
W/O
844365
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00138
PipeID
P09798
Time
12:25 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7936
Sewer Name
JOINT OUTFALL C - UNIT 7B
City
LONG BEACH
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
08
Purpose
Routine Assessment
Project
RFIR_WO_844365_TV03125_AUG2020
Sewer Type
Siphon
Material
Reinforced Concrete Pipe
Shape
Circular
Height
33 in.
Width
18 in.
Upstream MH
C 0334
Downstream MH
C 0335
Dir. of Survey
Upstream
Length Surveyed
2.1 ft.
Total Length
2.1 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole C 0334 to C 0335
MH: C 0334MH: C 0335upstream0 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES0 ft. MSA - Survey Abandoned - UP LEG SIPHON FROM DN STREAM MH0.1 ft. MGO - General Observation - AIRLINE OBSERVED @ 12 0'CLOCK - D/S MH2.1 ft. MWM - Water Mark, 30 %of cross sectional area2.1 ft. AMH - Downstream Manhole, Survey Begins - C 03342.1 ft. MWL - Water Level, 20 %of cross sectional area

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Survey Abandoned - UP LEG SIPHON FROM DN STREAM MH

    2.1 ft. - Survey Abandoned - UP LEG SIPHON FROM DN STREAM MH

Observations (6)

DistanceCodeObservation
2.1SAV
0MWM
2.1MSAUP LEG SIPHON FROM DN STREAM MH
0AMHC 0334
0MWL
2MGOAIRLINE OBSERVED @ 12 0'CLOCK - D/S MH

Properties (7)

additional_info
SC411796
custom_field_three
AGGREGATE VISIBLE
custom_field_two
3
customer
1
datetime
2020-07-30T00:25:45-07:00
documentation
PROPIPE
is_lateral_inspection
false